EP2SGX60EF1152I4 Altera, EP2SGX60EF1152I4 Datasheet - Page 133

IC STRATIX II GX 60K 1152-FBGA

EP2SGX60EF1152I4

Manufacturer Part Number
EP2SGX60EF1152I4
Description
IC STRATIX II GX 60K 1152-FBGA
Manufacturer
Altera
Series
Stratix® II GXr
Datasheet

Specifications of EP2SGX60EF1152I4

Number Of Logic Elements/cells
60440
Number Of Labs/clbs
3022
Total Ram Bits
2544192
Number Of I /o
534
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
1152-FBGA
Family Name
Stratix II GX
Number Of Logic Blocks/elements
60440
# I/os (max)
534
Frequency (max)
732.1MHz
Process Technology
SRAM
Operating Supply Voltage (typ)
1.2V
Logic Cells
60440
Ram Bits
2544192
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
1152
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Not Compliant
Other names
544-2186

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2SGX60EF1152I4
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2SGX60EF1152I4
Manufacturer:
ALTERA
0
Part Number:
EP2SGX60EF1152I4N
Manufacturer:
ALTERA
Quantity:
534
Part Number:
EP2SGX60EF1152I4N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2SGX60EF1152I4N
Manufacturer:
ALTERA
0
Part Number:
EP2SGX60EF1152I4N
Manufacturer:
ALTERA
Quantity:
300
Part Number:
EP2SGX60EF1152I4N
0
Altera Corporation
October 2007
Table 2–32
strength control.
Open-Drain Output
Stratix II GX devices provide an optional open-drain (equivalent to an
open collector) output for each I/O pin. This open-drain output enables
the device to provide system-level control signals (for example, interrupt
and write enable signals) that can be asserted by any of several devices.
Bus Hold
Each Stratix II GX device I/O pin provides an optional bus-hold feature.
The bus-hold circuitry can hold the signal on an I/O pin at its last-driven
state. Since the bus-hold feature holds the last-driven state of the pin until
the next input signal is present, an external pull-up or pull-down resistor
is not needed to hold a signal level when the bus is tri-stated.
Note to
(1)
3.3-V LVTTL
3.3-V LVCMOS
2.5-V LVTTL/LVCMOS
1.8-V LVTTL/LVCMOS
1.5-V LVCMOS
SSTL-2 Class I
SSTL-2 Class II
SSTL-18 Class I
SSTL-18 Class II
HSTL-18 Class I
HSTL-18 Class II
HSTL-15 Class I
HSTL-15 Class II
Table 2–32. Programmable Drive Strength
The Quartus II software default current setting is the maximum setting for each
I/O standard.
I/O Standard
Table
shows the possible settings for the I/O standards with drive
2–32:
I
Setting (mA) for Column
OH
24, 20, 16, 12, 8, 4
24, 20, 16, 12, 8, 4
/ I
12, 10, 8, 6, 4, 2
OL
12, 10, 8, 6, 4
12, 10, 8, 6, 4
12, 10, 8, 6, 4
20, 18, 16, 8
16, 12, 8, 4
20, 18, 16
20, 18, 16
24, 20, 16
Current Strength
8, 6, 4, 2
I/O Pins
12, 8
Stratix II GX Device Handbook, Volume 1
Note (1)
Stratix II GX Architecture
I
OH
Setting (mA) for Row
/ I
OL
12, 10, 8, 6, 4
10, 8, 6, 4
Current Strength
8, 6, 4, 2
I/O Pins
12, 8, 4
12, 8, 4
8, 6, 4
12, 8
8, 4
4, 2
16
2–125

Related parts for EP2SGX60EF1152I4