SDV-DM6 AC100/110 Omron, SDV-DM6 AC100/110 Datasheet - Page 45

no-image

SDV-DM6 AC100/110

Manufacturer Part Number
SDV-DM6 AC100/110
Description
Sensor Hardware & Accessories VOLTAGE SENSOR
Manufacturer
Omron
Datasheets

Specifications of SDV-DM6 AC100/110

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Current Converter Settings
Determining the Number of Primary
Conductor Runs
Determine the number of passes and the tap setting from the table
above. For example, if the current setting range is 2 to 5 A, there are
four passes and the tap setting is 20.
Pass the wires through the holes from the same direction. It doesn’t
matter which wires go through which holes.
Tap Setting
In tap setting, insert the setting screw into the required tap hole with
a screwdriver. After setting, be sure to replace the cover.
The following circuit can be used to check SAO-@ and SET-3@ characteristics.
SET-3
Current
Converter
Checking Operation
X/a
One conductor pass
200 VAC, 3-phase,
50/60 Hz
R
A A A
(The conductors pass
through the holes once.)
R
S
R
Primary conductor pass adjustment
T
R
OMRON Corporation
SET-3A
SURRENT
CONVERTER
No.
DATE
2 5 0 5 3
1 9 8 3
Control voltage
100 V
C
CC
Four conductor passes
3
2
(The conductors pass
through the holes four times.)
1
4
MADE IN JAPAN
20
40
60
8
Tap holes
5
7
6
SAO
Current
Sensor
X
Pushbutton
switch
3 SD: Three-phase voltage regulator
A:
CC:
X:
R
:
100 VAC
AC ammeter
Cycle counter
Auxiliary relay (15 A)
Resistor
Selecting the Current Converter
The current requirements of the motor determine whether the SET-
3A or SET-3B Current Converter should be used.
Single-phase Motor Use
The diagram below shows how to connect an SAO-@ Current Sensor
to a single-phase motor. There is a model available for use with a sin-
gle phase circuit.
Pass the required number of conductor runs through any two of the
three holes in the SET-3@ Current Converter. Even when wired as
shown in the diagram, the operating current will change, so it is nec-
essary to change the current SV as well.
Multiply the desired operating current by 0.77 to find the appropriate
current SV.
For example, if the desired operating current is 10 A, set the current
SV to 0.77 x 10 A = 7.7 A.
The SAO-@ is adjusted for 3-phase use, so verify operation in tests
with the actual load before operation.
1 to 2.5
2 to 5
4 to 10
8 to 20
16 to 40
32 to 80
64 to 160
Current range
Current Sensor
Motor
0.25
0.5
1
2
4
8
16
Decal no.
M
Current Sensor
SET
8
4
2
1
Passes
Current Converter
20
40
80
Fixed
SAO
SAO
settings
Tap
SET-3A
SET-3B
Model
43