ENC28J60-I/SP Microchip Technology, ENC28J60-I/SP Datasheet - Page 49

IC ETHERNET CTRLR W/SPI 28DIP

ENC28J60-I/SP

Manufacturer Part Number
ENC28J60-I/SP
Description
IC ETHERNET CTRLR W/SPI 28DIP
Manufacturer
Microchip Technology
Datasheets

Specifications of ENC28J60-I/SP

Package / Case
28-DIP (0.300", 7.62mm)
Controller Type
Ethernet Controller, MAC/10Base-T
Interface
SPI
Voltage - Supply
3.1 V ~ 3.6 V
Current - Supply
160mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Through Hole
Input Voltage Range (max)
5.5 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
Through Hole
Operating Supply Voltage
3.1 V to 3.6 V
Supply Current (max)
180 mA
Product
Ethernet Controllers
Standard Supported
IEEE 802.3
Data Rate
10 Mbps
Ethernet Connection Type
10Base-T
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
DM163024 - BOARD DEMO PICDEM.NET 2AC164123 - BOARD DAUGHTER ETH PICTAIL PLUSAC164121 - BOARD DAUGHTER PICTAIL ETHERNET
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ENC28J60-I/SP
Manufacturer:
MICROCHIP
Quantity:
6 500
Part Number:
ENC28J60-I/SP
Manufacturer:
MICROCHIP
Quantity:
2 000
Part Number:
ENC28J60-I/SP
Manufacturer:
MICROCHIP
Quantity:
5 000
Company:
Part Number:
ENC28J60-I/SP
Quantity:
1 150
8.0
To minimize the processing requirements of the host
controller, the ENC28J60 incorporates several different
receive filters which can automatically reject packets
which are not needed. Six different types of packet
filters are implemented:
• Unicast
• Pattern Match
• Magic Packet™
• Hash Table
• Multicast
• Broadcast
© 2006 Microchip Technology Inc.
RECEIVE FILTERS
Preliminary
The individual filters are all configured by the ERXFCON
register (Register 8-1). More than one filter can be active
at any given time. Additionally, the filters can be config-
ured by the ANDOR bit to either logically AND, or
logically OR, the tests of several filters. In other words,
the filters may be set so that only packets accepted by
all active filters are accepted, or a packet accepted by
any one filter is accepted. The flowcharts in Figure 8-1
and Figure 8-2 show the effect that each of the filters will
have depending on the setting of ANDOR.
The device can enter Promiscuous mode and receive
all packets by clearing the ERXFCON register. The
proper setting of the register will depend on the
application requirements.
ENC28J60
DS39662B-page 47