DS21Q43AT Maxim Integrated Products, DS21Q43AT Datasheet - Page 20

IC FRAMER E1 QUAD 5V IND 128TQFP

DS21Q43AT

Manufacturer Part Number
DS21Q43AT
Description
IC FRAMER E1 QUAD 5V IND 128TQFP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS21Q43AT

Controller Type
E1 Framer
Interface
Parallel/Serial
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
32mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
128-TQFP, 128-VQFP
Dc
0319
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS21Q43AT
Quantity:
6
Part Number:
DS21Q43AT
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS21Q43AT
Manufacturer:
DALLAS
Quantity:
1 000
Part Number:
DS21Q43AT
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
DS21Q43AT
Quantity:
290
Part Number:
DS21Q43AT+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS21Q43AT+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS21Q43ATN
Manufacturer:
DALLAS
Quantity:
20 000
CCR2: COMMON CONTROL REGISTER 2 (Address=1A Hex)
AUTOMATIC ALARM GENERATION
When either CCR2.4 or CCR2.5 is set to 1, the DS21Q43A monitors the receive side to determine if any
of the following conditions are present: loss of receive frame synchronization, AIS alarm (all 1s) re-
ception, or loss of receive carrier (or signal). If any one (or more) of the above conditions is present, then
the DS21Q43A will either force an AIS alarm (if CCR2.5=1) or a Remote Alarm (CCR2.4=1) to be
transmitted via the TPOS and TNEG pins. It is an illegal state to have both CCR2.4 and CCR2.5 set to 1
at the same time.
(MSB)
ECUS
SYMBOL
LOTCMC
VCRFS
RSERC
ECUS
AAIS
ARA
-
-
VCRFS
POSITION
CCR2.7
CCR2.6
CCR2.5
CCR2.4
CCR2.3
CCR2.2
CCR2.1
CCR2.0
AAIS
NAME AND DESCRIPTION
Error Counter Update Select.
0=update error counters once a second
1=update error counters every 62.5 ms (500 frames)
VCR Function Select.
0=count BiPolar Violations (BPVs)
1=count Code Violations (CVs)
Automatic AIS Generation.
0=disabled
1=enabled
Automatic Remote Alarm Generation.
0=disabled
1=enabled
RSER Control.
0=allow RSER to output data as received under all conditions
1=force RSER to 1 under loss of frame alignment conditions
Loss of Transmit Clock Mux Control. Determines whether the
transmit side formatter should switch to the ever-present RCLK
if the TCLK should fail to transition (see Figure 1-1).
0=do not switch to RCLK if TCLK stops
1=switch to RCLK if TCLK stops
Not Assigned. Should be set to 0 when written.
Not Assigned. Should be set to 0 when written.
ARA
20 of 60
RSERC
LOTCMC
-
DS21Q43A
(LSB)
-

Related parts for DS21Q43AT