IDT82V2048EBBG IDT, Integrated Device Technology Inc, IDT82V2048EBBG Datasheet - Page 45

IC LINE INTERFACE UNIT 208-PBGA

IDT82V2048EBBG

Manufacturer Part Number
IDT82V2048EBBG
Description
IC LINE INTERFACE UNIT 208-PBGA
Manufacturer
IDT, Integrated Device Technology Inc
Type
Line Interface Units (LIUs)r
Datasheet

Specifications of IDT82V2048EBBG

Protocol
E1
Voltage - Supply
3.13 V ~ 3.47 V
Mounting Type
Surface Mount
Package / Case
208-PBGA
Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Drivers/receivers
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
800-1704
82V2048EBBG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82V2048EBBG
Manufacturer:
IDT
Quantity:
5
Part Number:
IDT82V2048EBBG
Manufacturer:
IDT Integrated Device Technolo
Quantity:
135
Part Number:
IDT82V2048EBBG
Manufacturer:
NSC
Quantity:
60
Part Number:
IDT82V2048EBBG
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
OCTAL CHANNEL T1/E1/J1 SHORT HAUL LINE INTERFACE UNIT
4.2.5
Table-36 MAINT0: Maintenance Function Control Register 0
Table-37 MAINT1: Maintenance Function Control Register 1
PRBS_INV
PATT_CLK
PATT[1:0]
Symbol
Symbol
ATAO
ARLP
AISE
LAC
RLP
DLP
ALP
NETWORK DIAGNOSTICS CONTROL REGISTERS
-
-
(R/W, Address = 0AH,2AH,4AH,6AH,8AH,AAH,CAH,EAH)
(R/W, Address = 0BH,2BH,4BH,6BH,8BH,ABH,CBH,EBH)
6-5
7-4
Bit
Bit
4
3
2
0
7
3
2
1
0
1
Default
Default
0000
00
0
0
0
0
0
0
0
0
0
0
Selects reference clock for transmitting internal pattern
Automatic Remote Loopback Control
Remote loopback enable
Reserved
These bits select the internal pattern and insert it into the transmit data stream.
= 00: normal operation (PATT_CLK = 0) / insert all zeros (PATT_CLK = 1)
= 01: insert All Ones
= 10: insert PRBS (E1: 2
= 11: insert programmable Inband Loopback activate or deactivate code
= 0: uses TCLKn as the reference clock
= 1: uses MCLK as the reference clock
Inverts PRBS
= 0: PRBS data is not inverted
= 1: PRBS data is inverted before transmission and detection
The LOS/AIS criterion is selected as below:
= 0: G.775 (E1) / T1.231 (T1/J1)
= 1: ETSI 300233 & I.431 (E1) / I.431 (T1/J1)
AIS enable during LOS
= 0: AIS insertion on RDPn/RDNn/RCLKn is disabled during LOS
= 1: AIS insertion on RDPn/RDNn/RCLKn is enabled during LOS
Automatically Transmit All Ones (enabled only when PATT[1:0] = 01)
= 0: disabled
= 1: Automatically Transmit All Ones pattern at TTIPn/TRINGn during LOS.
Reserved
= 0: disables Automatic Remote Loopback (normal transmit and receive operation)
= 1: enables Automatic Remote Loopback
= 0: disables remote loopback (normal transmit and receive operation)
= 1: enables remote loopback
Analog loopback enable
= 0: disables analog loopback (normal transmit and receive operation)
= 1: enables analog loopback
Digital loopback enable
= 0: disables digital loopback (normal transmit and receive operation)
= 1: enables digital loopback
15
-1) or QRSS (T1/J1: 2
45
20
Description
Description
-1)
TEMPERATURE RANGES
INDUSTRIAL

Related parts for IDT82V2048EBBG