Description
16 Bit MCU, 64KB Flash, 8KB RAM, 60 MHz, 44 Pin, MCPWM,QEI, 3 OpAmp, 4 Comp, PTG
Manufacturer
Microchip Technology
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC24EP64MC204-E/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
dsPIC33EPXXXGP50X, dsPIC33EPXXXMC20X/50X, AND PIC24EPXXXGP/MC20X
REGISTER 16-15: FCLCONx: PWM FAULT CURRENT-LIMIT CONTROL REGISTER
DS70657F-page 244
bit 7-3
bit 2
bit 1-0
Note 1:
2:
If the PWMLOCK Configuration bit (FOSCSEL<6>) is a ‘1’, the IOCONx register can only be written after
the unlock sequence has been executed.
These bits should be changed only when PTEN = 0. Changing the clock selection during operation will
yield unpredictable results.
FLTSRC<4:0>: Fault Control Signal Source Select bits for PWM Generator #
11111 = Fault 32 (default)
11110 = Reserved
01100 = Reserved
01011 = Comparator 4
01010 = Op amp/Comparator 3
01001 = Op amp/Comparator 2
01000 = Op amp/Comparator 1
00111 = Reserved
00110 = Reserved
00101 = Reserved
00100 = Reserved
00011 = Fault 4
00010 = Fault 3
00001 = Fault 2
00000 = Fault 1
FLTPOL: Fault Polarity bit for PWM Generator #
1 = The selected Fault source is active-low
0 = The selected Fault source is active-high
FLTMOD<1:0>: Fault Mode bits for PWM Generator #
11 = Fault input is disabled
10 = Reserved
01 = The selected Fault source forces PWMxH, PWMxL pins to FLTDAT values (cycle)
00 = The selected Fault source forces PWMxH, PWMxL pins to FLTDAT values (latched condition)