MAX1464AAI+ Maxim Integrated Products, MAX1464AAI+ Datasheet - Page 26

IC SENSOR SIGNAL COND 28-SSOP

MAX1464AAI+

Manufacturer Part Number
MAX1464AAI+
Description
IC SENSOR SIGNAL COND 28-SSOP
Manufacturer
Maxim Integrated Products
Type
Signal Conditionerr
Datasheet

Specifications of MAX1464AAI+

Input Type
Analog
Output Type
Logic
Interface
SPI
Current - Supply
890µA
Mounting Type
Surface Mount
Package / Case
28-SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Low-Power, Low-Noise Multichannel
Sensor Signal Processor
CPU Cycles required:
Description:
Perform a 16-bit move operation from port-X to the A-
register.
The port-X contents are unchanged.
The previous contents of A-register are overwritten
and lost.
The port-X can be any of the CPU ports.
PC is incremented once to point to the next instruction
in program memory.
Two’s-complement data format is preserved.
No branching occurs.
No other registers are affected.
WRX
Op-code:
Operation:
CPU Cycles required:
Description:
Perform a 16-bit move operation from the A-register to
port-X.
The A-register contents are unchanged.
The previous contents of port-X are overwritten
and lost.
The port-X can be any of the CPU ports.
PC is incremented once to point to the next instruction
in program memory.
Two’s-complement data format is preserved.
No branching occurs.
No other registers are affected.
26
______________________________________________________________________________________
1 cycle
Port-X ← A-register
PC-register ← PC + 1 (point to next instruction)
1 cycle
Write Port X
1110 XXXX
BINARY
EXh
MLT
Op-code:
Operation:
CPU Cycles required:
Description:
Perform a 16-bit by 16-bit arithmetic multiplication of
the M-register and the N-register producing a 32-bit
result. The 32-bit result is stored in two 16-bit registers;
the A-register receives the most significant word of the
result and the M-register receives the least significant
word of the result.
The A-register must be cleared to zero (CLX A) before
executing the MLT instruction. The previous contents of
the A-register are overwritten and lost.
The previous contents of the M-register are overwritten
and lost.
The contents of the N-register are not altered.
The register op code must be 3h.
PC is incremented once to point to the next instruction
in program memory.
Two’s-complement data format is preserved.
No branching occurs.
No other registers are affected.
Multiply
A-register | M-register ← N-register x M-register
PC-register ← PC + 1 (point to next instruction)
16 cycles
1111 0011
BINARY
F3h