LTC4305IGN Linear Technology, LTC4305IGN Datasheet - Page 8

no-image

LTC4305IGN

Manufacturer Part Number
LTC4305IGN
Description
IC BUFFER BUS 2WR ADDRESS 16SSOP
Manufacturer
Linear Technology
Datasheet

Specifications of LTC4305IGN

Applications
Multiplexer with Amplifier
Interface
SMBus (2-Wire/I²C)
Voltage - Supply
2.2 V ~ 5.5 V
Package / Case
16-SSOP
Mounting Type
Surface Mount
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LTC4305IGN
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC4305IGN#PBF
Manufacturer:
LT
Quantity:
1 626
Part Number:
LTC4305IGN#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
OPERATIO
LTC4305
8
Control Register Bit Definitions
Register 0 (00h)
Note: Masters write to Register 0 to reset the fault circuitry after a fault
has occurred and been resolved. Because Register 0 is Read-Only, no
other functionality is affected.
* For Type, “R/W” = Read Write, “R” = Read Only
BIT NAME
d7 Downstream
d6 ALERT1 Logic State
d5 ALERT2 Logic State
d4 Reserved
d3 Reserved
d2 Failed Connection
d1 Latched Timeout
d0 Timeout Real Time
Connected
Attempt
U
TYPE* DESCRIPTION
R
R
R
R
R
R
R
R
Indicates if upstream bus is connected
to any downstream buses
0 = upstream bus disconnected from
all downstream buses
1 = upstream bus connected to one or
more downstream buses
Logic state of ALERT1 pin, noninverting
Logic state of ALERT2 pin, noninverting
Not Used
Not Used
Indicates if an attempt to connect to a
downstream bus failed because the
“Connection Requirement” bit in
Register 2 was low and the
downstream bus was low
0 = Failed connection attempt occurred
1 = No failed attempts at connection
occurred
Latched bit indicating if a timeout has
occurred and has not yet been cleared.
0 = no latched timeout
1 = latched timeout
Indicates real-time status of Stuck Low
Timeout Circuitry
0 = no timeout is occurring
1 = timeout is occurring
Register 1 (01h)
* For Type, “R/W” = Read Write, “R” = Read Only
d5-d0 Reserved
BIT NAME
d7
d6
Upstream
Accelerators
Enable
Downstream
Accelerators
Enable
TYPE* DESCRIPTION
R/W Activates upstream rise time
R/W Activates downstream rise time
R
accelerator currents
0 = upstream rise time accelerator
currents inactive (default)
1 = upstream rise time accelerator
currents active
accelerator currents
0 = downstream rise time accelerator
currents inactive (default)
1 = downstream rise time accelerator
currents active
Not Used
4305f