SP5004EGP Xeltek, SP5004EGP Datasheet - Page 44
![no-image](/images/manufacturer_photos/0/7/719/xeltek_sml.jpg)
SP5004EGP
Manufacturer Part Number
SP5004EGP
Description
SUPERPRO 5004EGP PROGRAMMER
Manufacturer
Xeltek
Series
SuperPro®r
Type
Gang-Universal Programmerr
Specifications of SP5004EGP
Contents
Programmer, AC Adapter, Cable, CD
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EEPROM, EPROM, FLASH, MCU, NVRAM, PLD
Other names
415-1051
Edit Auto Screen
The Auto function organizes the different functions of the device into a sequential
group and carries out the functions in order, similar to a batch command.
When you select Edit Auto on the Settings screen, the system displays the Edit
Auto screen, illustrated below. The illustration is a sample for the device ATMEL
AT89C51.
The Device Functions column displays all operations for the device.
The Auto column lists the operations in order of execution. For the sample in the
illustration, the operation execution order is Erase, Blank_check, Program, Verify.
1. Select Add to add the highlighted function in the Device Function column to
2. Select Delete to delete the highlighted function in the Auto column. You can
3. Select Delete All to remove all the functions from the Auto column.
Superpro
the end of the Auto column. You can also double‐click the highlighted function
in the Device Function column to add it to the Auto column.
also double‐click the highlighted function in the Auto column to delete it.
®
5004GP User’s Guide
44