74HCT2G66DP,125 NXP Semiconductors, 74HCT2G66DP,125 Datasheet - Page 5

IC SWITCH DUAL SPST 8TSSOP

74HCT2G66DP,125

Manufacturer Part Number
74HCT2G66DP,125
Description
IC SWITCH DUAL SPST 8TSSOP
Manufacturer
NXP Semiconductors
Series
74HCTr
Datasheet

Specifications of 74HCT2G66DP,125

Package / Case
8-TSSOP
Function
Switch
Circuit
2 x SPST - NO
Voltage Supply Source
Single Supply
Voltage - Supply, Single/dual (±)
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Switch Configuration
SPST
On Resistance (max)
41 Ohm (Typ) @ 4.5 V
On Time (max)
13 ns (Typ) @ 4.5 V
Off Time (max)
13 ns (Typ) @ 4.5 V
Supply Voltage (max)
5.5 V
Supply Voltage (min)
4.5 V
Maximum Power Dissipation
300 mW
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
74HCT2G66DP-G
74HCT2G66DP-G
935272944125

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
74HCT2G66DP,125
Manufacturer:
NXP Semiconductors
Quantity:
4 750
NXP Semiconductors
9. Recommended operating conditions
Table 6.
Voltages are referenced to GND (ground = 0 V).
[1]
10. Static characteristics
Table 7.
Voltages are referenced to GND (ground = 0 V).
74HC_HCT2G66
Product data sheet
Symbol Parameter
V
V
V
V
T
Δt/ΔV
Symbol Parameter
74HC2G66
V
V
I
I
I
I
I
S(OFF)
S(ON)
CC
amb
CC
I
O
SW
IH
IL
To avoid drawing V
exceed 0.4 V. If the switch current flows into pin nZ, no V
voltage drop across the switch, but the voltage at pins nY and nZ may not exceed V
HIGH-level
input voltage
LOW-level
input voltage
input leakage current
OFF-state
leakage current
ON-state
leakage current
supply current
supply voltage
input voltage
output voltage
switch voltage
ambient temperature
input transition rise
and fall rate
Recommended operating conditions
Static characteristics
CC
current out of pin nZ, when switch current flows in pin nY, the voltage drop across the bidirectional switch must not
Conditions
V
V
V
V
nE; V
Conditions
V
V
V
V
V
V
V
V
nY or nZ; V
nY or nZ; V
nE, nY and nZ = V
CC
CC
CC
CC
CC
CC
CC
CC
CC
CC
CC
CC
V
V
V
V
CC
CC
CC
CC
= 2.0 V
= 4.5 V
= 6.0 V
= 10.0 V
= 2.0 V
= 2.0 V
= 4.5 V
= 6.0 V
= 9.0 V
= 4.5 V
= 6.0 V
= 9.0 V
I
= V
All information provided in this document is subject to legal disclaimers.
= 6.0 V
= 9.0 V
= 6.0 V
= 9.0 V
CC
CC
CC
[1]
Rev. 8 — 23 September 2010
or GND
= 9.0 V; see
= 9.0 V; see
CC
CC
or GND
current will flow out of terminal nY. In this case there is no limit for the
Figure 6
Figure 7
Min
−40
2.0
0
0
0
-
-
-
-
74HC2G66; 74HCT2G66
74HC2G66
Dual single-pole single-throw analog switch
1.67
Typ
+25
5.0
-
-
-
-
-
-
3.15
Min
1.5
4.2
6.3
−40 °C to +85 °C
-
-
-
-
-
-
-
-
-
-
CC
+125
Max
10.0
V
V
V
625
139
or GND.
83
35
Typ
CC
CC
CC
1.2
2.4
3.2
4.7
0.8
2.1
2.8
4.3
0.1
0.1
-
-
-
-
[1]
Min
−40
4.5
Max
1.35
±0.1
±0.2
0
0
0
0.5
1.8
2.7
1.0
1.0
-
-
-
-
10
20
-
-
-
-
74HCT2G66
−40 °C to +125 °C Unit
1.67
Typ
+25
5.0
3.15
Min
-
-
-
-
-
-
1.5
4.2
6.3
-
-
-
-
-
-
-
-
-
-
© NXP B.V. 2010. All rights reserved.
+125
Max
V
V
V
139
5.5
CC
CC
CC
-
-
-
Max
1.35
±0.1
±0.2
0.5
1.8
2.7
1.0
1.0
20
40
-
-
-
-
Unit
V
V
V
V
°C
ns/V
ns/V
ns/V
ns/V
5 of 23
V
V
V
V
V
V
V
V
μA
μA
μA
μA
μA
μA

Related parts for 74HCT2G66DP,125