PCF8563P NXP Semiconductors, PCF8563P Datasheet - Page 8

PCF8563P

Manufacturer Part Number
PCF8563P
Description
Manufacturer
NXP Semiconductors
Datasheet

Specifications of PCF8563P

Bus Type
Serial (2-Wire, I2C)
Date Format
DW:DM:M:Y
Time Format
HH:MM:SS
Operating Supply Voltage (typ)
2.5/3.3/5V
Package Type
PDIP
Operating Supply Voltage (max)
5.5V
Operating Supply Voltage (min)
1.8V
Operating Temperature Classification
Industrial
Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Pin Count
8
Mounting
Through Hole
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PCF8563P
Manufacturer:
NXP
Quantity:
5 510
Part Number:
PCF8563P
Manufacturer:
NXP
Quantity:
10 000
Part Number:
PCF8563P
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
PCF8563P/F4
Manufacturer:
PULES
Quantity:
2 450
Part Number:
PCF8563P/F4
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
PCF8563P/F4112
Manufacturer:
NXP Semiconductors
Quantity:
1 912
NXP Semiconductors
PCF8563
Product data sheet
Fig 6.
COUNTDOWN COUNTER
When bits TIE and AIE are disabled, pin INT will remain high-impedance.
Interrupt scheme
8.3.2.1 Interrupt output
TE
Bits TF and AF:
timer countdown, TF is set to logic 1. These bits maintain their value until overwritten
using the interface. If both timer and alarm interrupts are required in the application, the
source of the interrupt can be determined by reading these bits. To prevent one flag being
overwritten while clearing another, a logic AND is performed during a write access.
Bits TIE and AIE:
TF or AF is asserted, respectively. The interrupt is the logical OR of these two conditions
when both AIE and TIE are set.
Countdown timer interrupts:
an internal clock and is dependent on the selected source clock for the countdown timer
and on the countdown value n. As a consequence, the width of the interrupt pulse varies
(see
Table 7.
[1]
[2]
Source clock (Hz)
4096
64
1
1
60
from interface:
from interface:
TF and INT become active simultaneously.
n = loaded countdown value. Timer stops when n = 0.
Table
set alarm
clear AF
clear TF
flag AF
INT operation (bit TI_TP = 1)
7).
All information provided in this document is subject to legal disclaimers.
SET
SET
When an alarm occurs, AF is set to logic 1. Similarly, at the end of a
These bits activate or deactivate the generation of an interrupt when
AF: ALARM
TF: TIMER
CLEAR
CLEAR
FLAG
Rev. 7 — 23 July 2010
INT period (s)
n = 1
1
1
1
1
The pulse generator for the countdown timer interrupt uses
8192
128
64
64
TRIGGER
GENERATOR 2
[2]
CLEAR
PULSE
[1]
to interface:
read TF
to interface:
read AF
TI_TP
0
1
n > 1
1
1
1
1
4096
64
64
64
TIE
AIE
Real-time clock/calendar
[2]
013aaa087