LH28F320S5HNS-ZP Sharp Electronics, LH28F320S5HNS-ZP Datasheet - Page 21

no-image

LH28F320S5HNS-ZP

Manufacturer Part Number
LH28F320S5HNS-ZP
Description
Manufacturer
Sharp Electronics
Datasheet

Specifications of LH28F320S5HNS-ZP

Cell Type
NOR
Density
32Mb
Access Time (max)
100ns
Interface Type
Parallel
Boot Type
Not Required
Address Bus
22/21Bit
Operating Supply Voltage (typ)
5V
Operating Temp Range
-40C to 85C
Package Type
SSOP
Program/erase Volt (typ)
4.5 to 5.5V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
4.5V
Operating Supply Voltage (max)
5.5V
Word Size
8/16Bit
Number Of Words
4M/2M
Supply Current
75mA
Mounting
Surface Mount
Pin Count
56
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LH28F320S5HNS-ZP
Manufacturer:
NATEL
Quantity:
22
4.10 Block Erase Suspend Command
The Block Erase Suspend command allows block-
erase interruption to read or (multi) word/byte-write
data in another block of memory. Once the block-
erase process starts, writing the Block Erase
Suspend command requests that the WSM suspend
the block erase sequence at a predetermined point in
the algorithm. The device outputs status register data
when read after the Block Erase Suspend command
is written. Polling status register bits SR.7 and SR.6
can determine when the block erase operation has
been suspended (both will be set to "1"). STS will
also transition to High Z. Specification t
the block erase suspend latency.
At this point, a Read Array command can be written
to read data from blocks other than that which is
suspended. A (Multi) Word/Byte Write command
sequence can also be issued during erase suspend
to program data in other blocks. Using the (Multi)
Word/Byte Write Suspend command (see Section
4.11), a (multi) word/byte write operation can also be
suspended. During a (multi) word/byte write operation
with block erase suspended, status register bit SR.7
will return to "0" and the STS (if set to RY/BY#)
output will transition to V
remain "1" to indicate block erase suspend status.
The only other valid commands while block erase is
suspended are Read Status Register and Block
Erase Resume. After a Block Erase Resume
command is written to the flash memory, the WSM
will continue the block erase process. Status register
bits SR.6 and SR.7 will automatically clear and STS
will return to V
is written, the device automatically outputs status
register data when read (see Figure 10). V
remain at V
erase) while block erase is suspended. RP# must
also remain at V
PPH1
OL
. After the Erase Resume command
IH
(the same V
. Block erase cannot resume until
OL
PP
. However, SR.6 will
level used for block
WHRH2
PP
defines
must
LHF32KZP
(multi) word/byte write operations initiated during
block erase suspend have completed.
4.11 (Multi) Word/Byte Write Suspend
The (Multi) Word/Byte Write Suspend command
allows (multi) word/byte write interruption to read data
in other flash memory locations. Once the (multi)
word/byte write process starts, writing the (Multi)
Word/Byte Write Suspend command requests that
the WSM suspend the (multi) word/byte write
sequence at a predetermined point in the algorithm.
The device continues to output status register data
when read after the (Multi) Word/Byte Write Suspend
command is written. Polling status register bits SR.7
and SR.2 can determine when the (multi) word/byte
write operation has been suspended (both will be set
to "1"). STS will also transition to High Z.
Specification t
write suspend latency.
At this point, a Read Array command can be written
to read data from locations other than that which is
suspended. The only other valid commands while
(multi) word/byte write is suspended are Read Status
Register and (Multi) Word/Byte Write Resume. After
(Multi) Word/Byte Write Resume command is written
to the flash memory, the WSM will continue the
(multi) word/byte write process. Status register bits
SR.2 and SR.7 will automatically clear and STS will
return to V
command is written, the device automatically outputs
status register data when read (see Figure 11). V
must remain at V
(multi) word/byte write) while in (multi) word/byte
write suspend mode. WP# must also remain at V
V
IL
.
Command
OL
WHRH1
. After the (Multi) Word/Byte Write
PPH1
defines the (multi) word/byte
(the same V
PP
level used for
Rev. 1.6
IH
18
PP
or