Specifications of CYNSE70064A-66BGC

Operating Supply Voltage (typ)
1.8V
Operating Supply Voltage (min)
1.7V
Operating Supply Voltage (max)
1.9V
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Package Type
BGA
Mounting
Surface Mount
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CYNSE70064A-66BGC
Manufacturer:
CY
Quantity:
44
Part Number:
CYNSE70064A-66BGC
Manufacturer:
CYPRESS
Quantity:
329
Part Number:
CYNSE70064A-66BGC
Manufacturer:
ALTERA
0
Part Number:
CYNSE70064A-66BGC
Manufacturer:
CYPRESS
Quantity:
7
Part Number:
CYNSE70064A-66BGC
Manufacturer:
CYPRESS/赛普拉斯
Quantity:
20 000
12.1
Table 12-1. SRAM Bus Address
12.2
The remainder of Section 12.0 describes SRAM Read and SRAM Write operations.
SRAM Read enables Read access to the off-chip SRAM containing associative data. The latency from the issuance of the Read
instruction to the address appearing on the SRAM bus is the same as the latency of the Search instruction and will be depend
on the value programmed for the TLSZ parameter in the device configuration register. The latency of the ACK from the Read
instruction is the same as the latency of the Search instruction to the SRAM address plus the HLAT programmed in the configu-
ration register. Note. SRAM Read is a blocking operation—no new instruction can begin until the ACK is returned by the selected
device performing the access.
SRAM Write enables Write access to the off-chip SRAM containing associative data. The latency from the second cycle of the
Write instruction to the address appearing on the SRAM bus is the same as the latency of the Search instruction and will depend
on the TLSZ value parameter programmed in the device configuration register. Note. SRAM Write is a pipelined operation—new
instruction can begin right after the previous command has ended.
During SRAM PIO Accesses, once the read or write command is given to the SRAM by the ASIC through the CYNSE70064A,
the data transfer takes place directly between the ASIC and the SRAM using a seperate dedicated databus instead of through
the CYNSE70064A.
12.3
SRAM Read enables Read access to the off-chip SRAM containing associative data. The latency from the issuance of the Read
instruction to the address appearing on the SRAM bus is the same as the latency of the Search instruction and will depend on
the TLSZ value parameter programmed in the device configuration register. The latency of the ACK from the Read instruction is
the same as the latency of the Search instruction to the SRAM address plus the HLAT programmed in the configuration register.
The following explains the SRAM Read operation in a table with only one device that has the following parameters: TLSZ = 00,
HLAT = 000, LRAM = 1, and LDEV = 1. Figure 12-1 shows the associated timing diagram. For the following description, the
selected device refers to the only device in the table because it is the only device to be accessed.
At the end of cycle 6, the selected device floats ACK in a three-state condition, and a new command can begin.
Document #: 38-02041 Rev. *F
• Cycle 1A: The host ASIC applies the Read instruction on the CMD[1:0] using CMDV = 1. The DQ bus supplies the address,
• Cycle 1B: The host ASIC continues to apply the Read instruction on the CMD[1:0] using CMDV = 1. The DQ bus supplies the
• Cycle 2: The host ASIC floats DQ[67:0] to a three-state condition.
• Cycle 3: The host ASIC keeps DQ[67:0] in a three-state condition.
• Cycle 4: The selected device starts to drive DQ[67:0] and drives ACK from High-Z to LOW.
• Cycle 5: The selected device drives the Read address on SADR[21:0]; it also drives ACK HIGH, CE_L LOW, and ALE_L LOW.
• Cycle 6: The selected device drives CE_L HIGH, ALE_L HIGH, the SADR bus, the DQ bus in a three-state condition, and
with DQ[20:19] set to 10, to select the SRAM address. The host ASIC selects the device for which the ID[4:0] matches the
DQ[25:21] lines. During this cycle, the host ASIC also supplies SADR[21:20] on CMD[8:7].
address with DQ[20:19] set to 10 to select the SRAM address.
ACK LOW.
Indirect Access
Command
PIO Read
PIO Write
Search
Generating an SRAM BUS Address
SRAM PIO Access
SRAM Read with a Table of One Device
Learn
SRAM Operation
Write/Read
Read
Write
Read
Write
C8
C8
C8
C8
C8
21
C7
C7
C7
C7
C7
20
[19:15]
ID[4:0]
ID[4:0]
ID[4:0]
ID[4:0]
ID[4:0]
CYNSE70064A
Index[14:0]
ADR[14:0]
SSR[14:0]
NFA[14:0]
ADR14:0]
[14:0]
Page 102 of 128

Related parts for CYNSE70064A-66BGC