STA333BW STMicroelectronics, STA333BW Datasheet - Page 29

no-image

STA333BW

Manufacturer Part Number
STA333BW
Description
Manufacturer
STMicroelectronics
Datasheet

Specifications of STA333BW

Operational Class
Class-AB
Audio Amplifier Output Configuration
1-Channel Mono/2-Channel Stereo
Audio Amplifier Function
Speaker
Total Harmonic Distortion
0.2@8Ohm@1W%
Single Supply Voltage (typ)
Not RequiredV
Dual Supply Voltage (typ)
3.3/5/9/12/15/18V
Power Supply Requirement
Quad
Rail/rail I/o Type
No
Power Supply Rejection Ratio
80dB
Single Supply Voltage (min)
Not RequiredV
Single Supply Voltage (max)
Not RequiredV
Dual Supply Voltage (min)
2.7/4.5V
Dual Supply Voltage (max)
3.6/21.5V
Operating Temp Range
-20C to 70C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
36
Package Type
PowerSSO EP
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STA333BW
Manufacturer:
st
Quantity:
864
Part Number:
STA333BW
Manufacturer:
ST
0
Part Number:
STA333BW
Manufacturer:
ST
Quantity:
20 000
Part Number:
STA333BW(-6LF)
Manufacturer:
ST
0
Part Number:
STA333BW/W
Manufacturer:
ST
0
Part Number:
STA333BW13
Manufacturer:
ST
0
Part Number:
STA333BW13TR
Manufacturer:
ST
0
Part Number:
STA333BW13TR
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
STA333BW13TR
Quantity:
1 000
Part Number:
STA333BWJ13TR
Manufacturer:
ST
Quantity:
20 000
Part Number:
STA333BWTR-9LF
Manufacturer:
ST
Quantity:
20 000
STA333BW
6.1.4
Configuration register D (addr 0x03)
High-pass filter bypass
Table 26.
The STA333BW features an internal digital high-pass filter for the purpose of AC coupling.
The purpose of this filter is to prevent DC signals from passing through a FFX amplifier. DC
signals can cause speaker damage. When HPB = 0, this filter is enabled.
De-emphasis
Table 27.
DSP bypass
Table 28.
Setting the DSPB bit bypasses the EQ function of the STA333BW.
Postscale link
Table 29.
Postscale function can be used for power-supply error correction. For multi-channel
applications running off the same power-supply, the postscale values can be linked to the
value of channel 1 for ease of use and update the values faster.
0
1
2
3
Bit
Bit
Bit
Bit
SME
D7
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
High-pass filter bypass
De-emphasis
DSP bypass
Postscale link
ZDE
D6
1
0
0
0
0
RST
RST
RST
RST
HPB
DEMP
DSPB
PSL
DRC
D5
0
Doc ID 13773 Rev 3
Name
Name
Name
Name
BQL
D4
0
1: bypass internal AC coupling digital high-pass filter
0: no de-emphasis
1: enable de-emphasis on all channels
0: normal operation
1: bypass of biquad and bass / treble functions
0: each channel uses individual postscale value
1: each channel uses channel 1 postscale value
PSL
D3
0
DSPB
Description
Description
Description
Description
D2
0
Register description
DEMP
D1
0
HPB
D0
0
29/67

Related parts for STA333BW