SI3201-KS Silicon Laboratories Inc, SI3201-KS Datasheet - Page 74

IC LINEFEED INTRFC SI321X 16SOIC

SI3201-KS

Manufacturer Part Number
SI3201-KS
Description
IC LINEFEED INTRFC SI321X 16SOIC
Manufacturer
Silicon Laboratories Inc
Series
ProSLIC®r
Datasheet

Specifications of SI3201-KS

Package / Case
16-SOIC (3.9mm Width) Exposed Pad, 16-eSOIC, 16-HSOIC
Function
CODEC
Interface
PCM, Serial, SPI
Number Of Circuits
1
Voltage - Supply
3.13 V ~ 5.25 V
Current - Supply
88mA
Power (watts)
800mW
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Includes
BORSCHT Functions, Ring Trip Detection
Product
SLIC
Supply Voltage (min)
3.13 V
Supply Current
88 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3201-KS
Manufacturer:
SILICON
Quantity:
18
Part Number:
SI3201-KS
Manufacturer:
SILICONIX
Quantity:
20 000
Part Number:
SI3201-KSR
Manufacturer:
ELANTEC
Quantity:
50 000
Part Number:
SI3201-KSR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Company:
Part Number:
SI3201-KSR
Quantity:
194
Si3210/Si3211
Register 15. Powerdown Control 2
Reset settings = 0000_0000
74
Name
Bit
7:6
Type
5
4
3
2
1
0
Bit
Reserved
ADCON
DACON
GMON
ADCM
DACM
Name
GMM
D7
Read returns zero.
Analog to Digital Converter Manual/Automatic Power Control.
0 = Automatic power control.
1 = Manual power control; ADCON controls on/off state.
Analog to Digital Converter On/Off Power Control.
When ADCM = 1:
0 = Analog to digital converter powered off.
1 = Analog to digital converter powered on.
ADCON has no effect when ADCM = 0.
Digital to Analog Converter Manual/Automatic Power Control.
0 = Automatic power control.
1 = Manual power control; DACON controls on/off state.
Digital to Analog Converter On/Off Power Control.
When DACM = 1:
0 = Digital to analog converter powered off.
1 = Digital to analog converter powered on.
DACON has no effect when DACM = 0.
Transconductance Amplifier Manual/Automatic Power Control.
0 = Automatic power control.
1 = Manual power control; GMON controls on/off state.
Transconductance Amplifier On/Off Power Control.
When GMM = 1:
0 = Analog to digital converter powered off.
1 = Analog to digital converter powered on.
GMON has no effect when GMM = 0.
D6
ADCM
R/W
D5
ADCON
Rev. 1.45
R/W
D4
Function
DACM
R/W
D3
DACON
R/W
D2
GMM
R/W
D1
GMON
R/W
D0