AT32UC3C0128C Atmel Corporation, AT32UC3C0128C Datasheet - Page 645

no-image

AT32UC3C0128C

Manufacturer Part Number
AT32UC3C0128C
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT32UC3C0128C

Flash (kbytes)
128 Kbytes
Pin Count
144
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
Hardware Qtouch Acquisition
No
Max I/o Pins
123
Ext Interrupts
144
Usb Transceiver
1
Quadrature Decoder Channels
2
Usb Speed
Full Speed
Usb Interface
Device + OTG
Spi
7
Twi (i2c)
3
Uart
5
Can
2
Lin
5
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
2000
Analog Comparators
4
Resistive Touch Screen
No
Dac Channels
4
Dac Resolution (bits)
12
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
36
Self Program Memory
YES
External Bus Interface
1
Dram Memory
sdram
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0 to 3.6 or 4.5 to 5.5
Operating Voltage (vcc)
3.0 to 3.6 or 4.5 to 5.5
Fpu
Yes
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
22
Input Capture Channels
12
Pwm Channels
20
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3C0128C-ALUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3C0128C-ALUT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3C0128C-ALUT
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
25.7.15
Name:
Access Type:
Offset:
Reset Value:
This register can only be written if the WPEN bit is cleared in the Write Protect Mode Register (if exists).
Table 25-24.
32117C–AVR-08/11
DRIFT: Drift compensation
RX_MPOL: Receiver Manchester Polarity
RX_PP: Receiver Preamble Pattern detected
RX_PL: Receiver Preamble Length
TX_MPOL: Transmitter Manchester Polarity
31
23
15
7
0
0
1
1
0: The USART can not recover from an important clock drift
1: The USART can recover from clock drift. The 16X clock mode must be enabled.
0: Logic Zero is coded as a zero-to-one transition, Logic One is coded as a one-to-zero transition.
1: Logic Zero is coded as a one-to-zero transition, Logic One is coded as a zero-to-one transition.
0: The receiver preamble pattern detection is disabled
1 - 15: The detected preamble length is RX_PL x Bit Period
0: Logic Zero is coded as a zero-to-one transition, Logic One is coded as a one-to-zero transition.
1: Logic Zero is coded as a one-to-zero transition, Logic One is coded as a zero-to-one transition.
Manchester Configuration Register
RX_PP
DRIFT
30
22
14
MAN
Read-write
0x50
0x30011004
6
0
1
0
1
Preamble Pattern default polarity assumed (RX_MPOL field not set)
ALL_ONE
ALL_ZERO
ZERO_ONE
ONE_ZERO
29
21
13
1
5
RX_MPOL
TX_MPOL
28
20
12
4
27
19
11
3
26
18
10
2
RX_PL
TX_PL
25
17
9
1
AT32UC3C
RX_PP
TX_PP
24
16
8
0
645

Related parts for AT32UC3C0128C