ATxmega128B1 Atmel Corporation, ATxmega128B1 Datasheet - Page 118

no-image

ATxmega128B1

Manufacturer Part Number
ATxmega128B1
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATxmega128B1

Flash (kbytes)
128 Kbytes
Pin Count
100
Max. Operating Frequency
32 MHz
Cpu
8-bit AVR
# Of Touch Channels
16
Hardware Qtouch Acquisition
No
Max I/o Pins
53
Ext Interrupts
53
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
3
Twi (i2c)
1
Uart
2
Segment Lcd
160
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
2000
Analog Comparators
4
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
AES/DES
Sram (kbytes)
8
Eeprom (bytes)
2048
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.6 to 3.6
Operating Voltage (vcc)
1.6 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
10
Input Capture Channels
10
Pwm Channels
10
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATxmega128B1-AU
Manufacturer:
TI
Quantity:
90
Part Number:
ATxmega128B1-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega128B1-AUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega128B1-CUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega128B1-U
Manufacturer:
FUJITSU
Quantity:
632
38. Errata
38.1
38.1.1
8330B–AVR–10/11
ATxmega64B1, ATxmega128B1
Rev. C
1. JTAG Revision is unchanged between Rev. B and Rev. C
1. AWeX fault protection restore is not done correctly in Pattern Generation Mode
JTAG Revision
AWeX fault protection restore is not done correct in Pattern Generation Mode
When a fault is detected the OUTOVEN register is cleared, and when fault condition is
cleared, OUTOVEN is restored according to the corresponding enabled DTI channels. For
Common Waveform Channel Mode (CWCM), this has no effect as the OUTOVEN is correct
after restoring from fault. For Pattern Generation Mode (PGM), OUTOVEN should instead
have been restored according to the DTILSBUF register.
Problem fix/Workaround
For CWCM no workaround is required.
For PGM in latched mode, disable the DTI channels before returning from the fault condi-
tion. Then, set correct OUTOVEN value and enable the DTI channels, before the direction
(DIR) register is written to enable the correct outputs again.
For PGM in cycle-by-cycle mode there is no workaround