AD5425 Analog Devices, AD5425 Datasheet - Page 6

no-image

AD5425

Manufacturer Part Number
AD5425
Description
High Bandwidth, CMOS 8-Bit Serial Interface Multiplying D/A Converter
Manufacturer
Analog Devices
Datasheet

Specifications of AD5425

Resolution (bits)
8bit
Dac Update Rate
2.47MSPS
Dac Settling Time
100ns
Max Pos Supply (v)
+5.5V
Single-supply
Yes
Dac Type
Current Out
Dac Input Format
Ser,SPI

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD5425YRM
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD5425YRMZ
Manufacturer:
TDK
Quantity:
1 000
Part Number:
AD5425YRMZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD5425YRMZ-REEL7
Manufacturer:
AVAGO
Quantity:
1 000
AD5425
ABSOLUTE MAXIMUM RATINGS
T
Table 3.
Parameter
V
V
I
Logic Input and Output
Operating Temperature Range
Storage Temperature Range
Junction Temperature
10-lead MSOP
Lead Temperature, Soldering
IR Reflow, Peak Temperature
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the
human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
OUT
DD
REF
A
Extended Industrial (Y Version)
θ
(10 secs)
(<20 secs)
= 25°C, unless otherwise noted.
1, I
, R
to GND
JA
Thermal Impedance
FB
OUT
to GND
2 to GND
1
Rating
−0.3 V to +7 V
−12 V to +12 V
−0.3 V to V
−0.3 V to V
−40°C to +125°C
−65°C to +150°C
150°C
206°C/W
300°C
235°C
DD
DD
+ 0.3 V
+ 0.3 V
Rev. A | Page 6 of 28
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only and functional operation of the device at these or
any other conditions above those listed in the operational
sections of this specification is not implied. Exposure to
absolute maximum rating conditions for extended periods may
affect device reliability. Only one absolute maximum rating may
be applied at any one time.
1
Overvoltages at SCLK, SYNC , DIN, and LDAC are clamped by internal diodes.
Current should be limited to the maximum ratings given.