ADM1060 Analog Devices, ADM1060 Datasheet - Page 39

no-image

ADM1060

Manufacturer Part Number
ADM1060
Description
Multi Power Supply Sequencer & Supervisor
Manufacturer
Analog Devices
Datasheet

Specifications of ADM1060

# Supplies Monitored
7
Volt Monitoring Accuracy
2.5%
# Output Drivers
9
Fet Drive/enable Output
Both
Package
28 ld TSSOP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADM1060
Manufacturer:
AD
Quantity:
5 510
Part Number:
ADM1060
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
ADM1060A
Manufacturer:
MAXIM
Quantity:
1 481
Part Number:
ADM1060ARU
Manufacturer:
AD
Quantity:
3 149
Part Number:
ADM1060ARU
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADM1060ARU-REEL7
Manufacturer:
ADI
Quantity:
2 980
Part Number:
ADM1060ARUCS
Manufacturer:
ADI
Quantity:
50
Part Number:
ADM1060ARUCZ0605R7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADM1060ARUCZ1003R7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADM1060ARUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADM1060ARUZ-REEL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
MASK REGISTERS
Table 52. List of Mask Registers
Hex Addr.
9D
9E
Table 53. Bit Map for ERRMASK1 Register 0x9D (Power-On Default 0x00)
Bit
7
6
5
4
3
2
1
0
Table 54. Bit Map for ERRMASK2 Register 0x9E (Power-On Default 0x00)
Bit
7–5
4
3
2
1
0
Name
Reserved
VP4MASK
VP3MASK
VP2MASK
VP1MASK
VHMASK
VB2MASK
VB1MASK
Name
Reserved
WDIMASK
GPI4MASK
GPI3MASK
GPI2MASK
GPI1MASK
Table
Table 53
Table 54
R/W
X
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
X
R/W
R/W
R/W
R/W
R/W
Name
ERRMASK1
ERRMASK2
If high, a fault occurring on the supply at input VP4 is ignored and not logged in LATF1.
If high, a fault occurring on the supply at input VP3 is ignored and not logged in LATF1.
If high, a fault occurring on the supply at input VP2 is ignored and not logged in LATF1.
If high, a fault occurring on the supply at input VP1 is ignored and not logged in LATF1.
If high, a fault occurring on the supply at input VH is ignored and not logged in LATF1.
Description
Unused
If high, a fault occurring on the supply at input VB2 is ignored and not logged in LATF1.
If high, a fault occurring on the supply at input VB1 is ignored and not logged in LATF1.
If high, a change in the logic level on the WDI output is ignored and not logged in LATF2.
If high, a change in the logic level on the GPI4 input is ignored and not logged in LATF2.
If high, a change in the logic level on the GPI3 input is ignored and not logged in LATF2.
If high, a change in the logic level on the GPI2 input is ignored and not logged in LATF2.
If high, a change in the logic level on the GPI1 input is ignored and not logged in LATF2.
Description
Unused
Default Power On Value
0x00
0x00
Rev. B | Page 39 of 52
Description
Error Mask Register for the seven SFDs
Error Mask Register for the four GPIs and the Watchdog Detector
ADM1060

Related parts for ADM1060