ST92F150CV1 STMicroelectronics, ST92F150CV1 Datasheet - Page 196

no-image

ST92F150CV1

Manufacturer Part Number
ST92F150CV1
Description
8-bit MCU
Manufacturer
STMicroelectronics
Datasheet

Specifications of ST92F150CV1

Internal Memory
Single Voltage FLASH up to 256 Kbytes, RAM up to 8Kbytes, 1K byte E3 (Emulated EEPROM)
Minimum Instruction Time
83 ns (24 MHz int. clock)

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST92F150CV1QB
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
ST92F150CV1QB
Manufacturer:
ST
0
Part Number:
ST92F150CV1QBTR
Manufacturer:
ST
0
Part Number:
ST92F150CV1QBTRE
Manufacturer:
ST
0
Part Number:
ST92F150CV1T3
Manufacturer:
ST
0
Part Number:
ST92F150CV1T3
Manufacturer:
ST
Quantity:
20 000
MULTIFUNCTION TIMER (MFT)
MULTIFUNCTION TIMER (Cont’d)
10.4.3.13 Autodiscrimination Mode
The phase between two pulses (respectively on in-
put pin B and input pin A) generates a one step up
(or down) count, so that the up/down control and
the counter clock are both external. Thus, if the ris-
ing edge of TxINB arrives when TxINA is at a low
level, the timer is incremented (no action if the ris-
ing edge of TxINB arrives when TxINA is at a high
level). If the falling edge of TxINB arrives when
TxINA is at a low level, the timer is decremented
(no action if the falling edge of TxINB arrives when
TxINA is at a high level).
Setting the UDC bit in the TCR register has no ef-
fect in this configuration.
10.4.3.14 TxINA = Trigger - TxINB = Ext. Clock
The signal applied to input pin A acts as a trigger
signal on REG0R, initiating the action for which the
register was programmed (i.e. a reload or cap-
196/429
9
ture), while the signal applied to input pin B is used
as the clock for the prescaler.
(*) The timer is in One shot mode and REG0R in
reload mode
10.4.3.15 TxINA = Ext. Clock - TxINB = Trigger
The signal applied to input pin B acts as a trigger,
performing a capture on REG1R, while the signal
applied to input pin A is used as the clock for the
prescaler.
10.4.3.16 TxINA = Trigger - TxINB = Gate
The signal applied to input pin A acts as a trigger
signal on REG0R, initiating the action for which the
register was programmed (i.e. a reload or cap-
ture), while the signal applied to input pin B acts as
a gate signal for the internal clock (i.e. the counter
runs only when the gate signal is at a low level).