A43E06161 AMIC Technology, Corp., A43E06161 Datasheet - Page 9

no-image

A43E06161

Manufacturer Part Number
A43E06161
Description
512K x 16-Bit x 2 Banks Synchronous DRAM
Manufacturer
AMIC Technology, Corp.
Datasheet
Simplified Truth Table
Note : 1. OP Code : Operand Code
PRELIMINARY
Register
Refresh
Bank Active & Row Addr.
Read &
Column Addr. Auto Precharge Enable
Write &
Column Addr. Auto Precharge Enable
Burst Stop
Precharge
Clock Suspend or
Active Power Down
Precharge Power Down Mode
DQM
No Operation Command
Deep Power Down Entry
Deep Power Down Exit
2. MRS can be issued only at both banks precharge state.
3. Auto refresh functions as same as CBR refresh of DRAM.
4. BA : Bank select address.
5. During burst read or write with auto precharge, new read write command cannot be issued.
6. DQM sampled at positive going edge of a CLK masks the data-in at the very CLK (Write DQM latency is 0),
7. After Deep Power Down mode exit, a full new initialization of the memory device is mandatory.
A0~A10/AP,BA : Program keys. (@MRS)
A new command can be issued after 2 clock cycle of MRS.
The automatical precharge without Row precharge command is meant by “Auto”.
Auto/Self refresh can be issued only at both precharge state.
If “Low” at read, write, Row active and precharge, bank A is selected.
If “High” at read, write, Row active and precharge, bank B is selected.
If A10/AP is “High” at Row precharge, BA is ignored and both banks are selected.
Another bank read write command can be issued at every burst length.
but makes the data-out Hi-Z state after 2 CLK cycles. (Read DQM latency is 2)
Mode Register Set
Auto Refresh
Self
Refresh
Auto Precharge Disable
Auto Precharge Disable
Bank Selection
Both Banks
Command
(July, 2005, Version 0.1)
Entry
Exit
Entry
Entry
Exit
Exit
CKEn-1 CKEn
H
H
H
H
H
H
H
H
H
H
H
H
L
L
L
L
H
H
X
X
H
H
H
X
X
X
X
X
L
L
L
L
CS
8
H
H
X
H
H
H
X
L
L
L
L
L
L
L
L
L
L
L
L
L
(V = Valid, X = Don’t Care, H = Logic High, L = Logic Low)
RAS CAS
H
X
H
H
H
H
X
X
H
X
V
X
H
X
H
X
L
L
L
L
X
H
H
H
H
X
H
H
X
X
H
X
V
X
H
X
X
L
L
L
L
WE
H
H
X
H
H
H
X
X
H
X
V
X
H
X
X
L
L
L
L
L
DQM
X
X
X
X
X
X
X
X
X
X
X
X
V
X
X
X
AMIC Technology, Corp.
BA A10/
V
V
V
V
X
OP CODE
AP
H
H
H
L
L
L
Row Addr.
X
X
X
X
X
X
X
X
X
Column
Column
A9~A0
A43E06161
Addr.
Addr.
X
Notes
1,2
4,5
4,5
3
3
3
3
4
4
4
6
7
7

Related parts for A43E06161