ADT7467 Analog Devices, Inc., ADT7467 Datasheet - Page 26

no-image

ADT7467

Manufacturer Part Number
ADT7467
Description
Dbcool Remote Thermal Monitor And Fan Controller
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADT7467
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADT7467A
Manufacturer:
AD
Quantity:
66
Part Number:
ADT7467A
Manufacturer:
PHILIPS
Quantity:
5 212
Part Number:
ADT7467AARQZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADT7467ARQ-REEL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADT7467ARQZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADT7467ARQZ
Quantity:
105
Company:
Part Number:
ADT7467ARQZ-REEL
Quantity:
83
Company:
Part Number:
ADT7467ARQZ-REEL
Quantity:
83
ADT7467
Configuring THERM Behavior
1.
2.
3.
4.
5.
Configure the relevant pin as the THERM timer input.
Setting Bit 1 ( THERM timer enable) of Configuration
Register 3 (Reg. 0x78) enables the THERM timer
monitoring functionality. This is disabled on Pin 9 by
default.
Setting Bits 0 and 1 (PIN9FUNC) of Configuration
Register 4 (Reg. 0x7D) enables THERM timer/output
functionality on Pin 9 (Bit 1, THERM , of Configuration
Register 3 must also be set). Pin 9 can also be used as
TACH4.
Select the desired fan behavior for THERM timer events.
Assuming that the fans are running, setting Bit 2 (BOOST
bit) of Configuration Register 3 (Reg. 0x78) causes all fans
to run at 100% duty cycle whenever THERM is asserted.
This allows fail-safe system cooling. If this bit is 0, the fans
run at their current settings and are not affected by
THERM events. If the fans are not already running when
THERM is asserted, the fans do not run to full speed.
Select whether THERM timer events should generate
SMBALERT interrupts.
When set, Bit 5 (F4P) of Mask Register 2 (Reg. 0x75)
masks SMBALERT s when the THERM timer limit value is
exceeded. This bit should be cleared if SMBALERT based
on THERM events are required.
Select a suitable THERM limit value.
This value determines whether an SMBALERT is generated
upon the first THERM assertion, or if only a cumulative
THERM assertion time limit is exceeded. A value of 0x00
causes an SMBALERT to be generated upon the first
THERM assertion.
Select a THERM monitoring time.
This value specifies how often OS or BIOS level software
checks the THERM timer. For example, BIOS could read
the THERM timer once an hour to determine the
cumulative THERM assertion time. If, for example, the
total THERM assertion time is <22.76 ms in Hour 1,
>182.08 ms in Hour 2, and >5.825 sec in Hour 3, this can
indicate that system performance is degrading significantly,
because THERM is asserting more frequently on an hourly
basis.
Rev. A | Page 26 of 80
Configuring the THERM Pin as an Output
In addition to monitoring THERM as an input, the ADT7467
can optionally drive THERM low as an output. In cases where
PROCHOT is bidirectional, THERM can be used to throttle the
processor by asserting PROCHOT . The user can preprogram
system-critical thermal limits. If the temperature exceeds a
thermal limit by 0.25°C, THERM asserts low. If the temperature
is still above the thermal limit on the next monitoring cycle,
THERM stays low. THERM remains asserted low until the
temperature is equal to or below the thermal limit. Because the
temperature for that channel is measured only once for every
monitoring cycle, it is guaranteed to remain low for at least one
monitoring cycle after THERM is asserted.
The THERM pin can be configured to assert low if the Remote 1,
local, or Remote 2 THERM temperature limits are exceeded by
0.25°C. The THERM temperature limit registers are at Registers
0x6A, 0x6B, and 0x6C, respectively. Setting Bit 3 of Registers
0x5F, 0x60, and 0x61 enables the THERM output feature for the
Remote 1, local, and Remote 2 temperature channels,
respectively. Figure 33 shows how the THERM pin asserts low
as an output in the event of a critical overtemperature.
An alternative method of disabling THERM is to program the
THERM temperature limit to –64°C or less in Offset 64 mode,
or to −128°C or less in twos complement mode; therefore, for
THERM temperature limit values less than –63°C or –128°C,
respectively, THERM is disabled.
Figure 33. Asserting THERM as an Output, Based on Tripping THERM Limits
THERM
THERM LIMIT
THERM LIMIT
Alternatively, OS or BIOS level software can timestamp
when the system is powered on. If an SMBALERT is
generated because the THERM timer limit has been
exceeded, another timestamp can be taken. The difference
in time can be calculated for a fixed THERM timer limit.
For example, if it takes one week for a THERM timer limit
of 2.914 sec to be exceeded and the next time it takes only
1 hour, this is an indication of a serious degradation in
system performance.
+0.25°C
TEMP
MONITORING
ADT7467
CYCLE