ADT7467 Analog Devices, Inc., ADT7467 Datasheet - Page 54

no-image

ADT7467

Manufacturer Part Number
ADT7467
Description
Dbcool Remote Thermal Monitor And Fan Controller
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADT7467
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADT7467A
Manufacturer:
AD
Quantity:
66
Part Number:
ADT7467A
Manufacturer:
PHILIPS
Quantity:
5 212
Part Number:
ADT7467AARQZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADT7467ARQ-REEL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADT7467ARQZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADT7467ARQZ
Quantity:
105
Company:
Part Number:
ADT7467ARQZ-REEL
Quantity:
83
Company:
Part Number:
ADT7467ARQZ-REEL
Quantity:
83
ADT7467
Enabling the THERM Trip Point as the Operating Point
Bits <4:2> of the dynamic T
enable/disable THERM monitoring to program the operating
point.
Dynamic T
<2> PHTR2 = 1 copies the Remote 2 current temperature to the
Remote 2 operating point register if THERM is asserted. The
operating point contains the temperature at which THERM is
asserted. This allows the system to run as quietly as possible
without affecting system performance.
PHTR2 = 0 ignores THERM assertions. The Remote 2
operating point register reflects its programmed value.
<3> PHTL = 1 copies the local current temperature to the local
temperature operating point register if THERM is asserted. The
operating point contains the temperature at which THERM is
asserted. This allows the system to run as quietly as possible
without affecting system performance.
PHTL = 0 ignores THERM assertions. The local temperature
operating point register reflects its programmed value.
<4> PHTR1 = 1 copies the Remote 1 current temperature to the
Remote 1 operating point register if THERM is asserted. The
operating point contains the temperature at which THERM is
asserted. This allows the system to run as quietly as possible
without affecting system performance.
PHTR1 = 0 ignores THERM assertions. The Remote 1
operating point register reflects its programmed value.
Enabling Dynamic T
Bits <7:5> of the dynamic T
enable/disable dynamic T
channels.
Dynamic T
<5> R2T = 1 enables the dynamic T
temperature channel. The chosen T
adjusted based on the current temperature, operating point, and
high and low limits for this zone.
R2T = 0 disables dynamic T
is not adjusted, and the channel behaves as described in the
section.
<6> LT = 1 enables dynamic T
temperature channel. The chosen T
adjusted based on the current temperature, operating point, and
high and low limits for this zone.
LT = 0 disables dynamic T
not adjusted, and the channel behaves as described in the
section.
MIN
MIN
Control Register 1 (0x36)
Control Register 1 (0x36)
MIN
MIN
Control Mode
MIN
MIN
MIN
MIN
control on the temperature
control. The T
MIN
control Register 1 (Reg. 0x36)
control Register 1 (Reg. 0x36)
control. The T
control on the local
MIN
MIN
MIN
value is dynamically
value is dynamically
control on the Remote 2
MIN
MIN
value chosen is
value chosen
Rev. A | Page 54 of 80
<7> R1T = 1 enables dynamic T
temperature channel. The chosen T
adjusted based on the current temperature, operating point, and
high and low limits for this zone.
R1T = 0 disables dynamic T
is not adjusted, and the channel behaves as described in the
Automatic Fan Control Overview section.
STEP 12: RAMP RATE FOR ACOUSTIC
ENHANCEMENT
The optimal ramp rate for acoustic enhancement can be
determined through system characterization after completing
the thermal optimization. If possible, the effect of each ramp
rate should be logged to determine the best setting for a given
solution.
Enhanced Acoustics Register 1 (Reg. 0x62)
<2:0> ACOU selects the ramp rate for PWM1.
Enhance Acoustics Register 2 (Reg. 0x63)
<2:0> ACOU3 selects the ramp rate for PWM3.
<6:4> ACOU2 selects the ramp rate for PWM2.
Another way to view the ramp rates is as the time it takes for the
PWM output to ramp up from 0% to 100% duty cycle for an
000 = 1 time slot = 35 sec
001 = 2 time slots = 17.6 sec
010 = 3 time slots = 11.8 sec
011 = 5 time slots = 7 sec
100 = 8 time slots = 4.4 sec
101 = 12 time slots =3 sec
110 = 24 time slots = 1.6 sec
111 = 48 time slots = 0.8 sec
000 = 1 time slot = 35 sec
001 = 2 time slots = 17.6 sec
010 = 3 time slots = 11.8 sec
011 = 5 time slots = 7 sec
100 = 8 time slots = 4.4 sec
101 = 12 time slots = 3 sec
110 = 24 time slots = 1.6 sec
111 = 48 time slots = 0.8 sec
000 = 1 time slot = 35 sec
001 = 2 time slots = 17.6 sec
010 = 3 time slots = 11.8 sec
011 = 5 time slots = 7 sec
100 = 8 time slots = 4.4 sec
101 = 12 time slots = 3 sec
110 = 24 time slots = 1.6 sec
111 = 48 time slots = 0.8 sec
MIN
control. The T
MIN
control on the Remote 1
MIN
value is dynamically
MIN
value chosen

Related parts for ADT7467