AUD10W Astec Powe, AUD10W Datasheet - Page 6

no-image

AUD10W

Manufacturer Part Number
AUD10W
Description
Ultra Low Profile Dc - Dc Module Pb-free Reflow Compatible And Rohs Compliant
Manufacturer
Astec Powe
Datasheet
Basic Operation and Features
Over Current Limit Inception (OCP)
The Isolated DC-DC converter limits output current when the current is over the maximum output current due to
abnormality such as overload or short circuit. When over current condition continues and output voltage decreases to the
point of low voltage protection, the DC-DC converter will be in latch up mode. To restore the output, remove the
abnormality and re-set the input voltage under 5V for 1 second minimum.
Over Voltage Protection (OVP)
The Isolated DC-DC converter stops the operation when the output voltage is over the specified Over Voltage Protection
point, the converter will be in latch up mode after 0.5ms*. To restore the output, re-set the input voltage under 5V for 1
second minimum.
Notes*: Output voltage might exceed the point at which OVP starts to function under the specific condition of transient
input voltage or output current change. Therefore, OVP is set to wait for the mask time 0.5ms.
Low Voltage Protection (LVP)
If output voltage is under the specified Low Voltage Protection point, the converter will halt the operation. After typical
500ms mask period, the converter will be in latch up mode. To restore the output, re-set the input voltage under 5V for 1
second minimum.
Remote On/Off Control (RC)
If RC pin is open or connected to –Vin, the converter is turned on. If RC is connected to +Vin, the converter is turned off.
Alarm Output (ALM)
The Alarm output will be down to the –Vin level (Open Drain Output) at the condition of Over Voltage Protection or Low
Voltage Protection. The maximum sink current in ALM pin is 10mA. When operating in parallel application, all operating
units can be simultaneously halt by connecting all the ALM pins together, in the condition of Over Voltage Protection or
Low Voltage Protection caused by any single converter. Maximum number for parallel operation is 10 units
Synchronous Turn On/Off
Connect the PO (parallel Operation) pins of all operating units together will synchronize the turn on / off time in parallel
application.
MODEL : AUD 10W
April 05 REVISION 02
MODULE PIN ASSIGNMENT
P1, 10, 11, 20
SERIES
P2, 3, 4
P16, 17
P18, 19
PIN #
P5, 6
P12
P13
P14
P15
NC
+Vo
-Vo
ALM
RC
PO
NC
+Vin
-Vin
DESIGNATION
Technical Reference Note
Ultra Low Profile
AUD 10W Series
Mechanical supplemental contact pins
+ Output
- Output
Alarm Output
Remote On/Off
Parallel Operation
-
+ Input
- Input
SHEET 6 OF 15

Related parts for AUD10W