P6002A Teccor Electronics, Inc., P6002A Datasheet - Page 147

no-image

P6002A

Manufacturer Part Number
P6002A
Description
solid state crowbar devices
Manufacturer
Teccor Electronics, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P6002AA
Manufacturer:
Littelfuse
Quantity:
45 000
Part Number:
P6002AA MCL
Manufacturer:
Littelfuse
Quantity:
45 000
Part Number:
P6002AAL
Manufacturer:
Littelfuse
Quantity:
45 000
Part Number:
P6002AB
Manufacturer:
Littelfuse
Quantity:
45 000
Part Number:
P6002AB MCL
Manufacturer:
Littelfuse
Quantity:
45 000
© 2002 Teccor Electronics
SIDACtor
®
Data Book and Design Guide
Note: Test conditions 2, 3, and 4 do not require the use of a wiring simulator or a secondary
Overvoltage Test Compliance
Equipment is deemed compliant if each of the following conditions are met during test:
• Absence of ignition or charring of the cheesecloth indicator
• Wiring simulator does not open during test condition 1 or 5
• For test condition 1, presented in Table 4.17, the integral I
After completion of the overvoltage tests, equipment must comply with either the Dielectric
Voltage-withstand Test requirements with all components in place or the Leakage Current
Test requirements.
Special Considerations Regarding the SIDACtor Device and UL 60950
The epoxy used for SIDACtor devices is UL recognized and the encapsulated body passes
UL 94V-0 requirements for flammability.
The only specific requirements of UL 60950 that pertain to the SIDACtor device itself are
the impulse test and the mandate that components be UL recognized. All other UL 60950
requirements pertain to the equipment being evaluated.
(Charring is deemed to have occurred when the threads are reduced to char by a
glowing or flaming condition.)
probe is less than 100 A
protector simulator. Any secondary protection simulators used in Tests 1 and 5
should be similar to the test fuse used in UL 497A, “Standard for Secondary
Protectors for Communications Circuits.”
2
s
.
4 - 23
UL 60950 3rd Edition (formerly UL 1950, 3rd edition)
2
t measured with a current
http://www.teccor.com
+1 972-580-7777

Related parts for P6002A