PM7312 pmc-sierra, PM7312 Datasheet - Page 183

no-image

PM7312

Manufacturer Part Number
PM7312
Description
Freedm 32a1024l Assp Telecom Standard Datasheet
Manufacturer
pmc-sierra
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
PM7312-BI
Quantity:
46
Part Number:
PM73121-RI
Manufacturer:
PMC
Quantity:
8 000
Part Number:
PM73121-RI
Manufacturer:
PMC
Quantity:
8 000
Part Number:
PM73121-RI-P
Manufacturer:
PMC
Quantity:
20 000
Part Number:
PM73122-BI-P
Quantity:
32
Part Number:
PM73122-BI-P
Quantity:
977
Part Number:
PM73123-PI
Quantity:
33
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.
Document No.: PMC-2021833, Issue 2
SYNCH_TRIB
SBIIP_LB
The SYNCH_TRIB bit is used to indicate whether the tributary is locked to the SBI SPE (i.e. is
in synchronous mode). If this bit is set then the tributary is locked. If this bit is not set, then the
tributary is free to float. This bit will default to off.
The SBIIP loop back bit selects the SBIIP extract loop back bus as the source for this tributary.
When SBIIP_LB is set to 1 LB_EXT_DATA, LB_EXT_LINKRATE, etc. are used as the input
data stream for the selected tributary. When SBIIP_LB is set to 0 the insert SBIIP bus is the
source for the selected tributary. Loop backs are only possible with floating tributaries, i.e.
cannot be used with synchronous T1 and E1 tributaries.
Note: Any write to a Tributary Control RAM location for a tributary will generate a
configuration reset on that tributary, irrespective of whether the data written to the tributary
control RAM location is unchanged from the previous value.
FREEDM 32A1024L ASSP Telecom Standard Product Data Sheet
Released
183