cs4297 Cirrus Logic, Inc., cs4297 Datasheet - Page 21

no-image

cs4297

Manufacturer Part Number
cs4297
Description
Crystalclear Soundfusion Audio Codec 97 Logic
Manufacturer
Cirrus Logic, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
cs4297-JQ
Manufacturer:
CRYSTALCI
Quantity:
326
Part Number:
cs4297-JQ
Manufacturer:
CRYSTAL
Quantity:
850
Part Number:
cs4297-JQ
Manufacturer:
CRYSTAL
Quantity:
1 000
Part Number:
cs4297-JQ
Manufacturer:
CS
Quantity:
20 000
Part Number:
cs4297A-JQ
Manufacturer:
CIRRUS
Quantity:
560
Part Number:
cs4297A-JQ
Manufacturer:
CRYSTAL
Quantity:
624
Part Number:
cs4297A-JQ
Manufacturer:
CS
Quantity:
20 000
Part Number:
cs4297A-JQ-EP
Manufacturer:
N/A
Quantity:
20 000
Part Number:
cs4297A-JQEP
Manufacturer:
CRYSTAL
Quantity:
20 000
Part Number:
cs4297AJQR
Manufacturer:
HIT
Quantity:
6 951
DS242F5
AC-Link Reset Modes
There are 3 methods to reset the CS4297. These are
defined in the AC’97 Specification as ‘Cold AC’97
Reset’, ‘Warm AC’97 Reset’, and AC’97 Register
Reset. A ‘Cold AC’97 Reset’ is required to restart
the AC-Link when bit PR5 is ‘set’ in register
(0x26).
Cold AC’97 Reset
A Cold Reset is performed simply by asserting RE-
SET# in accordance with the minimum timing
specifications in the Serial Port Timing section of
the data sheet. Once de-asserted, all of the AC’97
Registers will be reset to their default power-on
states and the BIT_CLK clock and SDATA_IN
signals will be reactivated. The timing of power-
up/reset events is discussed in detail in the Power
Management section of the data sheet.
Warm AC’97 Reset
The CS4297 may also be reactivated when the AC-
Link is powered down (refer to the PR4 bit descrip-
tion in the Power Management section of the data
sheet) by a Warm Reset. A Warm Reset allows the
AC-Link to be reactivated without losing informa-
tion in the AC’97 Registers. Warm Reset is initiat-
ed when the SYNC signal is driven high for at least
1 µs and then driven low in the absence of the
BIT_CLK clock signal. The BIT_CLK clock will
not restart until at least 2 normal BIT_CLK clock
periods (± 162.8 ns) after the SYNC signal is de-as-
serted.
CS4297
CrystalClear™ SoundFusion™ Audio Codec ’97
AC’97 Register Reset
The third reset mode provides a register reset to the
CS4297. This is available only when the CS4297’s
AC-Link is active and the Codec Ready bit is ‘set’.
The Register Reset allows all user accessible regis-
ters in the CS4297 to be reset to their default, pow-
er-up values. A Register Reset occurs when any
value is written to AC’97 Register 00h.
AC-Link Protocol Violation - Loss of SYNC
The CS4297 was designed to handle SYNC proto-
col violations. The following are situations where
the SYNC protocol has been violated:
The SYNC signal is not sampled high for exactly
16 BIT_CLK clock cycles at the start of an audio
frame.
The SYNC signal is not sampled high on the 256th
BIT_CLK clock period after the previous SYNC
assertion.
The SYNC signal goes active high before the 256th
BIT_CLK clock period after the previous SYNC
assertion.
Upon loss of synchronization with the AC’97 Con-
troller, the CS4297 will mute all analog outputs and
‘clear’ the Codec Ready bit in the serial data input
frame until 2 valid frames are detected. During this
detection period, the CS4297 will ignore all regis-
ter reads and writes and will discontinue the trans-
mission of PCM capture data.
21