output data are complemented also. When an EOM occurs before the current byte is fully shifted out,
dummy bits are inserted until the number of shifted bits is a multiple of 8.
For all states: At any time, a low level applied to STROBE puts the circuit into state 20, and a low level
applied to CONFB forces the state machine to state 1.
17.3 Standby/LVD Mode
Standby/LVD mode allows minimum current consumption to be achieved. Depending upon the value of
the LVDE bit, the circuit is in standby mode (state 60) or LVD mode (state 5 and 20).
LVDE = 0: The receiver is in standby; consumption is reduced to leakage current (current state after POR).
LVDE = 1: The LVD function is enabled; consumption is in the range of tens of microamperes.
The only way to exit this mode is to go back to configuration mode by applying a low level to CONFB.
17.4 Transition Time
Table 21
the logic conditions for that transition are met.
NOTES:
1
2
Freescale Semiconductor
Standby to SPI running, state 60 -> 1
Standby to receiver running, states 5 -> 5b, 20 -> 21
Off to receiver running, states 0 -> 0b, 10 -> 11
Configuration to receiver running,
states 1 -> (0b, 5b, 11, 21)
Receiver running to configuration mode,
state (0b, 5b, 11, 12, 13, 21, 22, 23) -> 1,
Receiver running to standby mode,
state 5b -> 5, (21, 22, 23) -> 20
Receiver running to off mode,
state 0b -> 0, (11, 12, 13) -> 10
See
Depending on the PLL status before entering configuration mode. For example, the transition time from standby to receiver
running (FSK modulation, 19.2 kBd, AFFC = 0, data manager enabled) is: 0.6 ms + 50 µs + (3 + 1)/19.2k = 970 µs.
Section 11.2, “Preamble, Identifier, Header, and
details the different times that must be considered for a given transition in the state machine, once
State x -> y
Transition
Table 21. Transition Time Definition
MC33596 Data Sheet, Rev. 3
Parameter 5.10
Message.”
Startup Time,
Oscillator
Crystal
√
√
√
parameter 5.1 or lock
time parameter 5.9
Lock time parameter
Lock time parameter
0 or lock time
PLL Timing
5.9
5.9
2
Preamble
Receiver
Time
√
√
√
1
On-to-Off Time,
Parameter 1.12
Receiver
Controller
√
√
39