dspic33fj128mc706at-i-pt Microchip Technology Inc., dspic33fj128mc706at-i-pt Datasheet - Page 93

no-image

dspic33fj128mc706at-i-pt

Manufacturer Part Number
dspic33fj128mc706at-i-pt
Description
High-performance, 16-bit Digital Signal Controllers
Manufacturer
Microchip Technology Inc.
Datasheet
REGISTER 7-3:
© 2009 Microchip Technology Inc.
bit 15
bit 7
Legend:
R = Readable bit
-n = Value at POR
bit 15
bit 14
bit 13
bit 12
bit 11
bit 10
bit 9
bit 8
bit 7
bit 6
bit 5
bit 4
SFTACERR
NSTDIS
R/W-0
R/W-0
NSTDIS: Interrupt Nesting Disable bit
1 = Interrupt nesting is disabled
0 = Interrupt nesting is enabled
OVAERR: Accumulator A Overflow Trap Flag bit
1 = Trap was caused by overflow of Accumulator A
0 = Trap was not caused by overflow of Accumulator A
OVBERR: Accumulator B Overflow Trap Flag bit
1 = Trap was caused by overflow of Accumulator B
0 = Trap was not caused by overflow of Accumulator B
COVAERR: Accumulator A Catastrophic Overflow Trap Flag bit
1 = Trap was caused by catastrophic overflow of Accumulator A
0 = Trap was not caused by catastrophic overflow of Accumulator A
COVBERR: Accumulator B Catastrophic Overflow Trap Flag bit
1 = Trap was caused by catastrophic overflow of Accumulator B
0 = Trap was not caused by catastrophic overflow of Accumulator B
OVATE: Accumulator A Overflow Trap Enable bit
1 = Trap overflow of Accumulator A
0 = Trap disabled
OVBTE: Accumulator B Overflow Trap Enable bit
1 = Trap overflow of Accumulator B
0 = Trap disabled
COVTE: Catastrophic Overflow Trap Enable bit
1 = Trap on catastrophic overflow of Accumulator A or B enabled
0 = Trap disabled
SFTACERR: Shift Accumulator Error Status bit
1 = Math error trap was caused by an invalid accumulator shift
0 = Math error trap was not caused by an invalid accumulator shift
DIV0ERR: Arithmetic Error Status bit
1 = Math error trap was caused by a divide by zero
0 = Math error trap was not caused by a divide by zero
DMACERR: DMA Controller Error Status bit
1 = DMA controller error trap has occurred
0 = DMA controller error trap has not occurred
MATHERR: Arithmetic Error Status bit
1 = Math error trap has occurred
0 = Math error trap has not occurred
DIV0ERR
OVAERR
R/W-0
R/W-0
INTCON1: INTERRUPT CONTROL REGISTER 1
dsPIC33FJXXXMCX06A/X08A/X10A
W = Writable bit
‘1’ = Bit is set
DMACERR
OVBERR
R/W-0
R/W-0
COVAERR
MATHERR
R/W-0
R/W-0
Preliminary
U = Unimplemented bit, read as ‘0’
‘0’ = Bit is cleared
COVBERR
ADDRERR
R/W-0
R/W-0
STKERR
OVATE
R/W-0
R/W-0
x = Bit is unknown
OSCFAIL
OVBTE
R/W-0
R/W-0
DS70594A-page 91
COVTE
R/W-0
U-0
bit 8
bit 0

Related parts for dspic33fj128mc706at-i-pt