p89c668hbbd NXP Semiconductors, p89c668hbbd Datasheet - Page 59

no-image

p89c668hbbd

Manufacturer Part Number
p89c668hbbd
Description
80c51 8-bit Flash Microcontroller Family
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P89C668HBBD
Manufacturer:
TI
Quantity:
25 600
Part Number:
P89C668HBBD
Manufacturer:
PHILPS
Quantity:
500
Company:
Part Number:
P89C668HBBD
Quantity:
271
Part Number:
p89c668hbbd/00,557
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Philips Semiconductors
PCA Watchdog Timer
An on-board watchdog timer is available with the PCA to improve the
reliability of the system without increasing chip count. Watchdog
timers are useful for systems that are susceptible to noise, power
glitches, or electrostatic discharge. Module 4 is the only PCA module
that can be programmed as a watchdog. However, this module can
still be used for other modes if the watchdog is not needed.
Figure 51 shows a diagram of how the watchdog works. The user
pre-loads a 16-bit value in the compare registers. Just like the other
compare modes, this 16-bit value is compared to the PCA timer
value. If a match is allowed to occur, an internal reset will be
generated. This will not cause the RST pin to be driven high.
In order to hold off the reset, the user has three options:
1. periodically change the compare value so it will never match the
2. periodically change the PCA timer value so it will never match
3. disable the watchdog by clearing the WDTE bit before a match
2002 Oct 28
80C51 8-bit Flash microcontroller family
16KB/32KB/64KB ISP/IAP Flash with 512B/1KB/2KB/8KB RAM
PCA timer,
the compare values, or
occurs and then re-enable it.
WRITE TO
CCAP4H
1
WRITE TO
CCAP4L
0
RESET
ENABLE
Figure 51. PCA Watchdog Timer m(Module 4 only)
CCAP4H
16–BIT COMPARATOR
CH
PCA TIMER/COUNTER
CIDL
––
ECOMn
WDTE
CCAP4L
CL
CAPPn
59
––
0
MODULE 4
timer is never disabled as in option #3. If the program counter ever
PCA timer (CH,CL). This code is given in the WATCHDOG routine in
MATCH
The first two options are more reliable because the watchdog
goes astray, a match will eventually occur and cause an internal
reset. The second option is also not recommended if other PCA
modules are being used. Remember, the PCA timer is the time
base for all modules; changing the time base for other modules
would not be a good idea. Thus, in most applications the first
solution is the best option.
Figure 52 shows the code for initializing the watchdog timer.
Module 4 can be configured in either compare mode, and the WDTE
bit in CMOD must also be set. The user’s software must periodically
change (CCAP4H,CCAP4L) to keep a match from occurring with the
Figure 52.
This routine should not be part of an interrupt service routine,
because if the program counter goes astray and gets stuck in an
infinite loop, interrupts will still be serviced and the watchdog will
keep getting reset. Thus, the purpose of the watchdog would be
defeated. Instead, call this subroutine from the main program within
2
16
CAPNn
count of the PCA timer.
––
0
P89C660/P89C662/P89C664/
MATn
––
1
TOGn
CPS1
X
CPS0
PWMn
0
ECCFn
ECF
X
P89C668
CMOD
(C1H)
RESET
CCAPM4
(C6H)
SU01105
Product data

Related parts for p89c668hbbd