z8f1621 ZiLOG Semiconductor, z8f1621 Datasheet - Page 188

no-image

z8f1621

Manufacturer Part Number
z8f1621
Description
High Performance 8-bit Microcontrollers
Manufacturer
ZiLOG Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
z8f1621AN020EC
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z8f1621AN020EC00TR
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z8f1621AN020EG
Manufacturer:
Zilog
Quantity:
356
Part Number:
z8f1621AN020EG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z8f1621AN020SC
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z8f1621AN020SC00TR
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z8f1621AN020SG
Manufacturer:
Zilog
Quantity:
918
Part Number:
z8f1621PM020SG
Manufacturer:
Zilog
Quantity:
673
Part Number:
z8f1621VN020SG
Manufacturer:
Zilog
Quantity:
6
PS019921-0308
DMA Control of the ADC
Follow the steps below for setting up the ADC and initiating continuous conversion:
1. Enable the desired analog input by configuring the general-purpose I/O pins for
2. Write to the ADC Control register to configure the ADC for continuous conversion.
3. When the first conversion in continuous operation is complete (after 5129 system
4. Thereafter, the ADC writes a new 10-bit data result to {ADCD_H[7:0],
5. To disable continuous conversion, clear the CONT bit in the ADC Control register
The Direct Memory Access (DMA) Controller can control operation of the ADC includ-
ing analog input selection and conversion enable. For more information on the DMA and
configuring for ADC operations, see
alternate function. This disables the digital input and output driver.
The bit fields in the ADC Control register may be written simultaneously:
clock cycles, plus the 40 cycles for power-up, if necessary), the ADC control logic
performs the following operations:
ADCD_L[7:6]} every 256 system clock cycles. An interrupt request is sent to the
Interrupt Controller when each conversion is complete.
to 0.
Write to the ANAIN[3:0] field to select one of the 12 analog input sources.
Set CONT to 1 to select continuous conversion.
Write to the VREF bit to enable or disable the internal voltage reference generator.
Set CEN to 1 to start the conversions.
CEN resets to 0 to indicate the first conversion is complete. CEN remains 0 for all
subsequent conversions in continuous operation.
An interrupt request is sent to the Interrupt Controller to indicate the conversion is
complete.
Direct Memory Access Controller
Z8 Encore! XP
Product Specification
Analog-to-Digital Converter
on page 161.
®