ak4644 AKM Semiconductor, Inc., ak4644 Datasheet - Page 64

no-image

ak4644

Manufacturer Part Number
ak4644
Description
Stereo Codec With Mic/hp/rcv-amp
Manufacturer
AKM Semiconductor, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ak4644EN
Manufacturer:
AKM
Quantity:
20 000
Part Number:
ak4644EN-L
Manufacturer:
AKM
Quantity:
20 000
Part Number:
ak4644ENL
Manufacturer:
NICHICON
Quantity:
2 554
ASAHI KASEI
(2)-2. READ Operations
Set the R/W bit = “1” for the READ operation of the AK4644. After transmission of data, the master can read the next
address’s data by generating an acknowledge instead of terminating the write cycle after the receipt of the first data word.
After receiving each data packet the internal 6-bit address counter is incremented by one, and the next data is
automatically taken into the next address. If the address exceeds 24H prior to generating a stop condition, the address
counter will “roll over” to 00H and the data of 00H will be read out.
The AK4644 supports two basic read operations: CURRENT ADDRESS READ and RANDOM ADDRESS READ.
(2)-2-1. CURRENT ADDRESS READ
The AK4644 contains an internal address counter that maintains the address of the last word accessed, incremented by
one. Therefore, if the last access (either a read or write) were to address n, the next CURRENT READ operation would
access data from the address n+1. After receipt of the slave address with R/W bit set to “1”, the AK4644 generates an
acknowledge, transmits 1-byte of data to the address set by the internal address counter and increments the internal
address counter by 1. If the master does not generate an acknowledge to the data but instead generates a stop condition,
the AK4644 ceases transmission.
(2)-2-2. RANDOM ADDRESS READ
The random read operation allows the master to access any memory location at random. Prior to issuing the slave address
with the R/W bit set to “1”, the master must first perform a “dummy” write operation. The master issues a start request, a
slave address (R/W bit = “0”) and then the register address to read. After the register address is acknowledged, the master
immediately reissues the start request and the slave address with the R/W bit set to “1”. The AK4644 then generates an
acknowledge, 1 byte of data and increments the internal address counter by 1. If the master does not generate an
acknowledge to the data but instead generates a stop condition, the AK4644 ceases transmission.
MS0477-E-01
SDA
SDA
S
A
R
S
T
T
Slave
Address
S
A
R
S
T
T
R/W="0"
Slave
Address
C
A
K
R/W="1"
Sub
Address(n)
A
C
K
Data(n)
Figure 66. CURRENT ADDRESS READ
Figure 67. RANDOM ADDRESS READ
C
A
K
S
T
A
R
T
S
Slave
Address
C
A
K
R/W="1"
Data(n+1)
C
A
K
- 64 -
Data(n)
A
C
K
Data(n+2)
A
C
K
Data(n+1)
C
A
K
C
A
K
A
C
K
Data(n+x)
A
C
K
Data(n+x)
C
A
K
O
S
T
P
P
A
C
K
[AK4644]
S
O
P
P
2006/10
T

Related parts for ak4644