emc2106 Standard Microsystems Corp., emc2106 Datasheet - Page 15

no-image

emc2106

Manufacturer Part Number
emc2106
Description
Emc2106 Dual Rpm-based Linear Fan Controller With Hardware Thermal Shutdown
Manufacturer
Standard Microsystems Corp.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
emc2106-DZK-TR
Manufacturer:
SMSC
Quantity:
20 000
Dual RPM-Based Linear Fan Controller with Hardware Thermal Shutdown
Datasheet
Chapter 3 Electrical Specifications
SMSC EMC2106
3.1
VDD = 3V to 3.6V, VDD_5V = 4.5V to 5.5V, T
Supply Voltage
Supply Current
(active)
CHARACTERISTIC
Voltage on 5V tolerant pins including VDD_5V
Voltage on VDD pin
Voltage on 2V tolerant pins
Voltage on any other pin to GND
Package Power Dissipation See
Junction to Ambient (θ
Operating Ambient Temperature Range
Storage Temperature Range
ESD Rating, All Pins, HBM
Note: Stresses above those listed could cause permanent damage to the device. This is a stress
Note 3.1
Note 3.2
Note 3.3
Electrical Specifications
rating only and functional operation of the device at any other condition above those indicated
in the operation sections of this specification is not implied. When powering this device from
laboratory or system power supplies, it is important that the Absolute Maximum Ratings not be
exceeded or device failure can result. Some power supplies exhibit voltage spikes on their
outputs when the AC power is switched on or off. In addition, voltage transients on the AC
power line may appear on the DC output. If this possibility exists, it is suggested that a clamp
circuit be used.
JA
SYMBOL
) See
All voltages are relative to ground.
The Package Power Dissipation specification assumes a recommended thermal via design
consisting of four 12mil vias connected to the ground plane with a 2x2mm thermal landing.
Junction to Ambient (θ
vias and a thermal landing, the θ
temperature increase.
V
I
DD
DD
Note 3.2
Note 3.1
Table 3.1 Absolute Maximum Ratings
Table 3.2 Electrical Specifications
MIN
3
A
JA
= -40°C to 85°C, all Typical values at T
DATASHEET
) is dependent on the design of the thermal vias. Without thermal
TYP
DC Power
3.3
2
noted.
15
JA
MAX
3.6
is approximately 52°C/W including localized PCB
3
-0.3 to 6.5
-0.3 to 4
-0.3 to 2.5
-0.3 to VDD + 0.3
1 up to T
40
-40 to 85°C
-55 to 150
2000
UNIT
mA
V
A
= 85°C
4 Conversions / second -
Dynamic Averaging Enabled
Fan Drivers enabled at max
PWM frequency
A
= 27°C unless otherwise
CONDITIONS
Revision 1.74 (05-08-08)
V
V
V
V
W
°C/W
°C
°C
V

Related parts for emc2106