hi-8599 Holt Integrated Circuits, Inc., hi-8599 Datasheet - Page 5

no-image

hi-8599

Manufacturer Part Number
hi-8599
Description
Transmitter With Line Driver And Dual Receivers
Manufacturer
Holt Integrated Circuits, Inc.
Datasheet
FUNCTIONAL DESCRIPTION (cont.)
TRANSMITTER
A block diagram of the transmitter section is shown in Figure 3.
FIFO OPERATION
The FIFO is loaded sequentially by first pulsing
and then
the 31 bit word in the next available position of the FIFO. If TX/R,
the transmitter ready flag is high (FIFO empty), then 8 words, each
31 bits long, may be loaded. If TX/R is low, then only the available
positions may be loaded. If all 8 positions are full, the FIFO ignores
further attempts to load data.
DATA TRANSMISSION
When ENTX goes high, enabling transmission, the FIFO positions
are incremented with the top register loading into the data
transmission shift register. Within 2.5 data clocks the first data bit
appears at either TXA(OUT) or TXB(OUT). The 31 bits in the data
transmission shift register are presented sequentially to the outputs
in the ARINC 429 format with the following timing:
The word counter detects when all loaded positions are transmitted
and sets the transmitter ready flag, TX/R, high.
ARINC DATA BIT TIME
WORD GAP TIME
PL2
NULL BIT TIME
DATA BIT TIME
to load byte 2. The control logic automatically loads
LOAD SHIFT REGISTER
31 BIT PARALLEL
8 X 31 FIFO
DATA BUS
FIGURE 3.
HIGH SPEED
10 Clocks
40 Clocks
5 Clocks
5 Clocks
TRANSMITTER BLOCK DIAGRAM
PL1
LOW SPEED
HOLT INTEGRATED CIRCUITS
320 Clocks
80 Clocks
40 Clocks
40 Clocks
to load byte 1
LOAD
BIT CLOCK
ADDRESS
WORD CLOCK
HI-8599
GENERATOR
5
BIT BD12
PARITY
TRANSMITTER PARITY
The parity generator counts the ONES in the 31-bit word. If the
BD12 control word bit is set low, the 32nd bit transmitted will
make parity odd. If the control bit is high, the parity is even.
SELF TEST
If the BD05 control word bit is set low, the digital outputs of the
transmitter are internally connected to the logic inputs of the
receivers, bypassing the analog bus interface circuitry. Data to
Receiver 1 is as transmitted and data to Receiver 2 is the
complement. All data transmitted during self test is also present
on the TXA(OUT) and TXB(OUT) line driver outputs.
TEST high forces TXA(OUT) and TXB(OUT) into the null state
regardless of the state of Bd05 control word bit.
SYSTEM OPERATION
The two receivers are independent of the transmitter. Therefore,
control of data exchanges is strictly at the option of the user. The
only restrictions are:
1.
2.
3.
4.
5.
The received data may be overwritten if not retrieved within
one ARINC word cycle.
The FIFO can store 8 words maximum and ignores attempts to
Byte 1 of the transmitter data must be loaded first.
Either byte of the received data may be retrieved first. Both
bytes must be retrieved to clear the data ready flag.
After ENTX, transmission enable, goes high it cannot go low
until TX/R, transmitter ready flag, goes high. Otherwise, one
ARINC word is lost during transmission.
load addition data if full.
CLOCK
DATA
SEQUENCER
NULL TIMER
DATA AND
WORD COUNTER
FIFO CONTROL
DATA CLOCK
SEQUENCER
CONTROL BIT
WORD GAP
COUNTER
LOADING
DIVIDER
AND
FIFO
AND
BD13
BIT
SEQUENCE
WORD COUNT
INCREMENT
START
LINE DRIVER
TXA(OUT)
TXB(OUT)
TEST
TX CLK
CLK
TX/R
ENTX
PL1
PL2
Taking

Related parts for hi-8599