IDT72V36100 IDT [Integrated Device Technology], IDT72V36100 Datasheet - Page 10

no-image

IDT72V36100

Manufacturer Part Number
IDT72V36100
Description
Manufacturer
IDT [Integrated Device Technology]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT72V36100L10PF
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT72V36100L10PF8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT72V36100L15PF
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT72V36100L15PF8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT72V36100L15PFI
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT72V36100LF5BBI
Manufacturer:
IDT
Quantity:
196
NOTES:
1. n = empty offset for PAE.
2. m = full offset for PAF.
3. As well as selecting serial programming mode, one of the default values will also
4. As well as selecting parallel programming mode, one of the default values will
IDT72V3640/50/60/70/80/90/110 3.3V HIGH DENSITY SUPERSYNC II
1,024 x 36, 2,048 x 36, 4,096 x 36, 8,192 x 36, 16,384 x 36, 32,768 x 36, 65,536 x 36, 131,072 x 36
be loaded depending on the state of FSEL0 & FSEL1.
also be loaded depending on the state of FSEL0 & FSEL1.
LD
LD
LD
LD
LD
H
H
H
H
LD
L
L
L
L
H
H
H
H
H
H
H
H
H
H
H
L
L
L
L
L
L
L
L
L
L
L
IDT72V3660, 72V3670, 72V3680, 72V3690
IDT72V36100, 72V36110
IDT72V3640, 72V3650
FSEL1
FSEL1
FSEL1
FSEL1
FSEL1
FSEL1
H
H
H
H
H
H
H
H
H
H
H
H
X
X
X
X
X
X
L
L
L
L
L
L
L
L
L
L
L
L
FSEL0
FSEL0
FSEL0
FSEL0
FSEL0
FSEL0
H
H
H
H
X
X
H
H
H
H
X
X
H
H
H
H
X
X
L
L
L
L
L
L
L
L
L
L
L
L
Program Mode
Program Mode
Program Mode
Offsets n,m
Offsets n,m
Offsets n,m
Parallel
Parallel
Parallel
Serial
Serial
Serial
16,383
1,023
8,191
4,095
2,047
1,023
511
255
127
511
255
127
511
255
127
63
31
15
63
31
15
7
3
7
(3)
(3)
(3)
(4)
(4)
(4)
TM
36-BIT FIFO
10
PROGRAMMING FLAG OFFSETS
72V3650/72V3660/72V3670/72V3680/72V3690/72V36100/72V36110 have
internal registers for these offsets. There are eight default offset values selectable
during Master Reset. These offset values are shown in Table 2. Offset values
can also be programmed into the FIFO in one of two ways; serial or parallel
loading method. The selection of the loading method is done using the LD (Load)
pin. During Master Reset, the state of the LD input determines whether serial
or parallel flag offset programming is enabled. A HIGH on LD during Master
Reset selects serial loading of offset values. A LOW on LD during Master Reset
selects parallel loading of offset values.
the current offset values. Offset values can be read via the parallel output port
Q
not possible to read the offset values in serial fashion.
the control pins and sequence for both serial and parallel programming modes.
For a more detailed description, see discussion that follows.
Master Reset, regardless of whether serial or parallel programming has been
selected. Valid programming ranges are from 0 to D-1.
SYNCHRONOUS vs ASYNCHRONOUS PROGRAMMABLE FLAG TIM-
ING SELECTION
72V36100/72V36110 can be configured during the Master Reset cycle with
either synchronous or asynchronous timing for PAF and PAE flags by use of
the PFM pin.
MRS), the PAF is asserted and updated on the rising edge of WCLK only and
not RCLK. Similarly, PAE is asserted and updated on the rising edge of RCLK
only and not WCLK. For detail timing diagrams, see Figure 17 for synchronous
PAF timing and Figure 18 for synchronous PAE timing.
MRS), the PAF is asserted LOW on the LOW-to-HIGH transition of WCLK and
PAF is reset to HIGH on the LOW-to-HIGH transition of RCLK. Similarly, PAE
is asserted LOW on the LOW-to-HIGH transition of RCLK. PAE is reset to HIGH
on the LOW-to-HIGH transition of WCLK. For detail timing diagrams, see Figure
19 for asynchronous PAF timing and Figure 20 for asynchronous PAE timing.
0
-Qn, regardless of the programming mode selected (serial or parallel). It is
Full and Empty Flag offset values are user programmable. The IDT72V3640/
In addition to loading offset values into the FIFO, it is also possible to read
Figure 3, Programmable Flag Offset Programming Sequence, summaries
The offset registers may be programmed (and reprogrammed) any time after
The IDT72V3640/72V3650/72V3660/72V3670/72V3680/72V3690/
If synchronous PAF/PAE configuration is selected (PFM, HIGH during
If asynchronous PAF/PAE configuration is selected (PFM, LOW during
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES

Related parts for IDT72V36100