act7006 Aeroflex Circuit Technology, act7006 Datasheet - Page 20

no-image

act7006

Manufacturer Part Number
act7006
Description
Act7005/7006 Single Package Solution Dual Transceiver, Protocol, Subsystem
Manufacturer
Aeroflex Circuit Technology
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACT7006
Manufacturer:
WSI
Quantity:
3
Aeroflex Circuit Technology
Pin #
42
40
49
51
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
56
90
60
1
Table 11 – Pin Number Description (continued)
Signal Name
DATA CHA
DATA CHA
DATA CHB
DATA CHB
DBCREQ
CLOCK
DONE
DB10
DB11
DB12
DB13
DB14
DB15
DB0
DB1
DB2
DB3
DB4
DB5
DB6
DB7
DB8
DB9
DS
6 MHz Master Clock.
DATA CHANNEL A. (BUS 0). This is the combined signals, RX
Data In and TX Data Out, that connect to the IN phase primary
terminal of the Bus Transformer.
DATA CHANNEL A. (BUS 0) This is the combined signals RX
Data In and TX Data Out, that connect to the OUT of phase
primary terminal of the Bus Transformer.
Same as DATA CHA, except for Channel B. (BUS 1).
Same as DATA CHA, except for Channel B. (BUS 1).
I/O DATA BUS. Data Bus for all SUBSYSTEM
READ and WRITE OPERATIONS.
16 BIT MODE
DB0 = LSB
DB15 = MSB
When used in 8 BIT MODE the data bus must be
connected as follows:
DB0 TO DB8
DB1 TO DB9
DB2 TO DB10
DB3 TO DB11
Dynamic Bus Control Request. If OPERATION Register bit i5 is
set LOW, this line will pulse LOW in response to a Valid
Dynamic Bus Control Mode Command, indicating
ACCEPTANCE of Bus Control Function.
Device Select. This signal must be low before the interface can
be selected for an I/O Read or Write function. The I/O Data Bus
will remain tri-stated, no operations will be executed when this
signal is high.
Low Pulse Indicates an I/O Operation has completed
20
DB4 TO DB12
DB5 TO DB13
DB6 TO DB14
DB7 TO DB15
DB0/DB8 = LSB
DB7/DB15 = MSB
8 BIT MODE
Signal Description
SCD7005 REV B 8/2/01
Plainview NY (516) 694-6700