UPD72042BGT NEC [NEC], UPD72042BGT Datasheet - Page 36

no-image

UPD72042BGT

Manufacturer Part Number
UPD72042BGT
Description
LSI DEVICE FOR Inter Equipment Bus (IEBus) PROTOCOL CONTROL
Manufacturer
NEC [NEC]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD72042BGT
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD72042BGT-E1
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD72042BGT-E1-A
Manufacturer:
MPS
Quantity:
2 001
Part Number:
UPD72042BGT-E1-A
Manufacturer:
NEC
Quantity:
20 000
[Broadcast bit]
[Number of arbitrations] (Number of retries)
communication. The PD72042B automatically retries communication as many times as the number set in this field.
36
The MCR register is used to set a master communication condition.
Set MCR while the value of MARQ of the FLG register is 0 (while master communication is not requested).
This bit is used to select broadcast or separate communication.
This field is used to set the maximum number of retry operations to be performed if arbitration is lost in master
b6
0
0
0
0
1
1
1
1
MCR
Master communication register
Bit 7 = 0: Broadcast
Bit 7 = 1: Separate communication
b5
0
0
1
1
0
0
1
1
b4
0
1
0
1
0
1
0
1
Broadcast bit
Number of retries
b7
0
1
2
3
4
5
6
7
Number of arbitrations
b6
Data Sheet S13990EJ3V0DS
b4
b3
Control bits
Address
Read/write
When reset : Undefined (the pre-
b0
MCR
: 0110B (6H)
: Write
vious data is held)
PD72042B