BUS-12-087 FCI-CONNECTOR [FCI connector], BUS-12-087 Datasheet - Page 11

no-image

BUS-12-087

Manufacturer Part Number
BUS-12-087
Description
Manufacturer
FCI-CONNECTOR [FCI connector]
Datasheet
NUMBER
TITLE
Ribcage™ II Printed Wiring Board Connector System
Copyright FCI
Form E-3334
Rev F
BUS-12-087
3.7.4 Shock - There shall be no evidence of physical or
3.7.5 Vibration - There shall be no evidence of physical or
3.7.6 Hydrogen Sulfide (H 2 S) Exposure - After exposure of the
mechanical damage when the mated connector is subjected to transient accelerations.
During and after each shock, the contacts shall evidence no discontinuity greater than
1 microsecond. The test shall be in accordance with MIL-STD-202, Method 213; the
following details shall apply:
(a)
(b)
(c)
mechanical damage when the mated connector is subjected to prolonged mechanical
vibration; during the vibration along each axis, the contacts shall evidence no
discontinuity greater than 1 microsecond. At the completion of the test, the contact
resistance shall not exceed the value specified in Table 1 (see paragraph 3.5.2). The
test shall be in accordance with MIL-STD-202, Method 204; the following details shall
apply:
(a)
(b)
(c)
mated connector to a moist H 2 S atmosphere, the low level circuit resistance shall not
exceed the value specified in Table 1 (see paragraph 3.5.2). The following details
shall apply:
(a)
(b)
(c)
TYPE
Test condition: A (50G, 11 ms half-sine)
Number of shocks: 3 shocks in each direction along three orthogonal axes (18
total)
Mounting: see Figure 5
Test condition: B (+_ 15G, 10 to 2,000 Hz)
Test duration: 4 hours along each of three orthogonal axes (12 hours total)
Mounting: See Figure 5.
Test medium: 3PPM H 2 S chemically produced in a moist environment
(desiccator)
Test temperature: 40 o C
Test duration: 48 hours
PRODUCT SPECIFICATION
PDM: Rev:M
STATUS:
PAGE
AUTHORIZED BY
CLASSIFICATION
C. Martinez
Released
11 of 21
UNRESTRICTED
Printed: Nov 28, 2010
REVISION
DATE
27 Feb 07
M
GS-01-001
.