FDC37B80X SMSC [SMSC Corporation], FDC37B80X Datasheet - Page 56

no-image

FDC37B80X

Manufacturer Part Number
FDC37B80X
Description
PC98/99 Compliant Enhanced Super I/O Controller with Keyboard/Mouse Wake-Up
Manufacturer
SMSC [SMSC Corporation]
Datasheet
is transferred to the host. Data is read from the
disk and CRC is computed and checked against
the previously-stored value.
Because data is not transferred to the host, TC
(pin 89) cannot be used to terminate this
command. By setting the EC bit to "1", an
implicit TC will be issued to the FDC. This
implicit TC will occur when the SC value has
decremented to 0 (an SC value of 0 will verify
256 sectors).
terminated by setting the EC bit to "0" and the
EOT value equal to the final sector to be
Note: If MT is set to "1" and the SC value is greater than the number of remaining formatted sectors
on Side 0, verifying will continue on Side 1 of the disk.
MT
0
0
0
0
1
1
1
1
This command can also be
EC
0
0
1
1
0
0
1
1
Table 24 - Verify Command Result Phase Table
SC = DTL
EOT
SC = DTL
EOT > # Sectors Per Side
SC
EOT
SC > # Sectors Remaining OR
EOT > # Sectors Per Side
SC = DTL
EOT
SC = DTL
EOT > # Sectors Per Side
SC
EOT
SC > # Sectors Remaining OR
EOT > # Sectors Per Side
# Sectors Remaining AND
# Sectors Remaining AND
# Sectors Per Side
# Sectors Per Side
# Sectors Per Side
# Sectors Per Side
SC/EOT VALUE
56
checked. If EC is set to "0", DTL/SC should be
programmed to 0FFH. Refer to Table 23 and
Table 24 for information concerning the values
of MT and EC versus SC and EOT value.
Definitions:
# Sectors Per Side = Number of formatted
sectors per each side of the disk.
# Sectors Remaining = Number of formatted
sectors left which can be read, including side 1
of the disk if MT is set to "1".
Success Termination
Result Phase Valid
Unsuccessful Termination
Result Phase Invalid
Successful Termination
Result Phase Valid
Unsuccessful Termination
Result Phase Invalid
Successful Termination
Result Phase Valid
Unsuccessful Termination
Result Phase Invalid
Successful Termination
Result Phase Valid
Unsuccessful Termination
Result Phase Invalid
TERMINATION RESULT