MAX1363EUB Maxim Integrated, MAX1363EUB Datasheet - Page 14

no-image

MAX1363EUB

Manufacturer Part Number
MAX1363EUB
Description
Analog to Digital Converters - ADC
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX1363EUB

Number Of Channels
4/2
Architecture
SAR
Conversion Rate
133 KSPs
Resolution
12 bit
Input Type
Single-Ended/Differential
Snr
Yes
Interface Type
I2C, Serial
Operating Supply Voltage
2.7 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Package / Case
uMAX
Maximum Power Dissipation
444.4 mW
Minimum Operating Temperature
- 40 C
Number Of Converters
1
Voltage Reference
4.096 V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX1363EUB+
Manufacturer:
MAXIM/美信
Quantity:
20 000
4-Channel, 12-Bit System Monitors with Programmable
Trip Window and SMBus Alert Response
Figure 8. Example of Writing Setup and Control Bytes
Figure 9. Example of Extended Setup Byte Writing
Table 2. Configuration Byte Format*
* Power-on defaults: 0x01
14
7(MSB)
BIT
6
5
4
3
2
1
0
______________________________________________________________________________________
CONFIG
SCAN1
SCAN0
NAME
SE/DIF
CS3
CS2
CS1
CS0
CONDITION
CONDITION
CH 0 LT [11:4] BYTE
START
START
START
START
The configuration byte always starts with 0.
SCAN1, SCAN0 = [0,0], scans from channel 0 to the upper channel chosen by CS1, CS0.
SCAN1, SCAN0 = [0,1], converts a single channel chosen by CS1, CS0 eight times.
SCAN1, SCAN0 = [1,0] monitor mode monitors from channel 0 to the upper channel chosen by CS1, CS0.
SCAN1, SCAN0 = [1,1], single channel conversion for the channel is chosen by CS0, CS1.
CS3, CS2 = [1,1] enables readback of monitor-mode setup data.
Selects the upper limit of the channel range used for the conversion sequence in scan modes SCAN = [0,0]
and monitor modes SCAN = [1,0].
Selects the conversion channel when SCAN = [0,1] or when SCAN = [1,1].
(Tables 5 and 6)
1 = single-ended inputs.
0 = differential inputs.
AIN0 and AIN1 form the first differential pair and AIN2 and AIN3 form the second differential pair. (See Tables
4 and 5.)
Selects single-ended or differential conversions. In single-ended mode, input-signal voltages are referenced
to GND. In differential mode, the voltage difference between two channels is measured.
When single-ended mode is used, the MAX1363/MAX1364 perform unipolar conversions regardless of the
UNI/BIP bit in the setup byte.
(Table 7)
FROM THE MASTER
FROM THE MASTER
ADDRESS
ADDRESS
A
R/W BIT FROM
THE MASTER
R/W BIT FROM
UT [11:8] BYTE
THE MASTER
CH 0 LT [3:0];
0
0
A
A
FROM THE MASTER
SETUP BYTE
BYTE FROM THE MASTER
A
CONFIGURATION
CH 0 UT [7:0] BYTE
1
DESCRIPTION
A
A
SPEED, BYTE FROM MASTER
A
ALARM RESET, SCAN
CH 1 LT [11:4] BYTE
BYTE FROM THE MASTER
SETUP
A
A
A
STOP
STOP

Related parts for MAX1363EUB