MAX1363EUB Maxim Integrated, MAX1363EUB Datasheet - Page 18

no-image

MAX1363EUB

Manufacturer Part Number
MAX1363EUB
Description
Analog to Digital Converters - ADC
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX1363EUB

Number Of Channels
4/2
Architecture
SAR
Conversion Rate
133 KSPs
Resolution
12 bit
Input Type
Single-Ended/Differential
Snr
Yes
Interface Type
I2C, Serial
Operating Supply Voltage
2.7 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Package / Case
uMAX
Maximum Power Dissipation
444.4 mW
Minimum Operating Temperature
- 40 C
Number Of Converters
1
Voltage Reference
4.096 V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX1363EUB+
Manufacturer:
MAXIM/美信
Quantity:
20 000
4-Channel, 12-Bit System Monitors with Programmable
Trip Window and SMBus Alert Response
When the MAX1363/MAX1364 receive a NACK, they
release SDA allowing the master to generate a STOP or
a repeated START condition.
The MAX1363/MAX1364 automatically monitor up to four
input channels. For systems with limited I
monitor mode allows the µC to set a window by
programming lower and upper thresholds during initial-
ization, and only intervening if the MAX1363/MAX1364
detect an alarm condition. This allows an interrupt-driven
approach as an alternative to continuously polling the
ADC with the µC. Monitor mode reduces processor over-
head and conserves I
The following shows an example of events in
monitor mode:
1) Fault condition(s) detected, INT asserted.
2) Host µC services interrupt and sends SMBus alert to
3) The MAX1363/MAX1364 release the INT.
4) Host µC reads the alarm-status register, latched-
5) Host µC services alarm(s); adjusts system parame-
6) Host µC resets the alarming channel. See the
7) Monitor mode resumes.
Figure 13. Example of Scan-Mode Conversions Using the External Clock, SCAN = 0,0 and 0,1
18
identify the alarming device. The MAX1363/
MAX1364 respond with the I
ing arbitration rules. (See the SMBus Alert section.)
fault register, and current-conversion results to
determine the alarming channel(s) and course
of action.
ters as needed and/or adjusts lower and upper
thresholds.
Configuring Monitor Mode section.
______________________________________________________________________________________
START
2
C bandwidth.
FROM THE MASTER
1, CH ADD, 10b/12b,
t
RESULT (4 MSBs)
ACQ
ADDRESS
Monitor-Mode Overview
2
C slave address, pend-
Monitor Mode
1
2
ACK
CONVERSION N
C bandwidth,
ACK
t
ACQ
RESULT N (8 LSBs)
1, CH ADD, 10b/12b
RESULT (4 MSBs)
8) If there is still an active fault, the device asserts INT
Writing SCAN1 and SCAN0 bits = [1,0] in the configura-
tion byte activates monitor mode. The MAX1363/
MAX1364 scan from channels 0 up to the channel
selected by [CS1:CS0] at a rate determined by the
scan delay bits. The MAX1363/MAX1364 compare the
conversion results with the lower and upper thresholds
for each channel. When any conversion exceeds the
threshold, the MAX1363/MAX1364 assert an interrupt
by pulling INT low (if enabled). The MAX1363/
MAX1364 set the corresponding flag bit in the alarm-
status register and write conversion results to the
latched-fault register to record the event causing the
alarm condition.
To write monitoring setup data, set the monitor-setup bit
(bit 0 in setup byte) to 1 to extend writing up to 104 bits
(13 bytes) of monitoring setup data. The number of bits
written to the MAX1363/MAX1364 depends on whether
the part is in single-ended or differential mode and
whether the upper channel limit is set by [CS1:CS0]
(Table 9).
Terminate writing at any time by using a STOP or
repeated START condition. Previous monitoring setup
data not overwritten remains valid.
A 1 written to the reset alarm CH_ clears the alarm, oth-
erwise no action occurs (Table 10). Deassert INT by
INT active state is randomly delayed with respect to the
conversion. Depending on the number of channels
scanned and the position in the channel scan sequence,
the maximum possible delay for asserting INT is five con-
version periods (37.5µs typ, Delay = 0,0,0).
t
ACQ
ACK
again. See step 1.
ACK
CONVERSION 1
RESULT (8 LSBs)
Configuring Monitor Mode
t
ACQ
ACK