MK30DX64VLK7R Freescale Semiconductor, MK30DX64VLK7R Datasheet - Page 7

no-image

MK30DX64VLK7R

Manufacturer Part Number
MK30DX64VLK7R
Description
ARM Microcontrollers - MCU Kinetis 64K Flex
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MK30DX64VLK7R

Rohs
yes
Core
ARM Cortex M4
Processor Series
MK30DX64
Data Bus Width
32 bit
Maximum Clock Frequency
72 MHz
Program Memory Size
64 KB
Data Ram Size
16 KB
On-chip Adc
Yes
Operating Supply Voltage
1.71 V to 3.6 V
Operating Temperature Range
- 40 C to + 105 C
Package / Case
LQFP-80
Mounting Style
SMD/SMT
A/d Bit Size
16 bit
A/d Channels Available
2
Interface Type
CAN, I2C, I2S, SPI, UART, USB
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Number Of Timers
2
On-chip Dac
Yes
Program Memory Type
Flash
Supply Voltage - Max
3.6 V
Supply Voltage - Min
1.71 V
3.6 Relationship between ratings and operating requirements
–∞
–∞
3.7 Guidelines for ratings and operating requirements
Follow these guidelines for ratings and operating requirements:
3.8 Definition: Typical value
A typical value is a specified value for a technical characteristic that:
Typical values are provided as design guidelines and are neither tested nor guaranteed.
Freescale Semiconductor, Inc.
Expected permanent failure
Expected permanent failure
• Never exceed any of the chip’s ratings.
• During normal operation, don’t exceed any of the chip’s operating requirements.
• If you must exceed an operating requirement at times other than during normal
• Lies within the range of values specified by the operating behavior
• Given the typical manufacturing process, is representative of that characteristic
operation (for example, during power sequencing), limit the duration as much as
possible.
during operation when you meet the typical-value conditions or other specified
conditions
Fatal range
Fatal range
Degraded operating range
- No permanent failure
- Possible decreased life
- Possible incorrect operation
K30 Sub-Family Data Sheet, Rev. 3, 11/2012.
Operating (power on)
Handling (power off)
Normal operating range
- No permanent failure
- Correct operation
No permanent failure
Handling range
Degraded operating range
- No permanent failure
- Possible decreased life
- Possible incorrect operation
Terminology and guidelines
Expected permanent failure
Expected permanent failure
Fatal range
Fatal range
7