XRT83SL314ES Exar, XRT83SL314ES Datasheet - Page 50

no-image

XRT83SL314ES

Manufacturer Part Number
XRT83SL314ES
Description
LIN Transceivers 14 CHT1/E1 LIUSH
Manufacturer
Exar
Datasheet

Specifications of XRT83SL314ES

Product Category
LIN Transceivers
Rohs
yes
XRT83SL314
REV. 1.0.1
If the LIU is interfaced to a Motorola type µP, it should be configured to operate in the Motorola mode. Motorola
type programmed I/O Read and Write operations are described below.
Motorola Mode Read Cycle
Whenever a Motorola type µP wishes to read the contents of a register, it should do the following.
Motorola Mode Write Cycle
Whenever a motorola type µP wishes to write a byte or word of data into a register within the LIU, it should do
the following.
The Motorola Read and Write timing diagram is shown in Figure 40. The timing specifications are shown in
Table 19.
1. Place the address of the target register on the address bus input pins ADDR[10:0].
2. While the µP is placing this address value on the address bus, the address decoding circuitry should
3. The µP should then toggle the TS pin "Low". This step causes the LIU to latch the contents of the address
4. Next, the µP should indicate that this current bus cycle is a Read operation by pulling the R/W input pin
5. Toggle the WE input pin "Low". This action enables the bi-directional data bus output drivers of the LIU.
6. After the µP toggles the WE signal "Low", the LIU will toggle the TA output pin "Low". The LIU does this in
7. After the µP detects the TA signal and has read the data, it can terminate the Read Cycle by toggling the
1. Place the address of the target register on the address bus input pins ADDR[10:0].
2. While the µP is placing this address value on the address bus, the address decoding circuitry should
3. The µP should then toggle the TS pin "Low". This step causes the LIU to latch the contents of the address
4. Next, the µP should indicate that this current bus cycle is a Write operation by pulling the R/W input pin
5. Toggle the WE input pin "Low". This action enables the bi-directional data bus output drivers of the LIU.
6. After the µP toggles the WE signal "Low", the LIU will toggle the TA output pin "Low". The LIU does this in
7. After the µP detects the TA signal and has read the data, it can terminate the Read Cycle by toggling the
5.3
assert the CS pin of the LIU, by toggling it "Low". This action enables further communication between the
µP and the LIU microprocessor interface block.
bus into its internal circuitry. At this point, the address of the register has now been selected.
"High".
order to inform the µP that the data is available to be read by the µP, and that it is ready for the next com-
mand.
WE input pin "High".
assert the CS pin of the LIU, by toggling it "Low". This action enables further communication between the
µP and the LIU microprocessor interface block.
bus into its internal circuitry. At this point, the address of the register has now been selected.
"Low".
order to inform the µP that the data has been written into the internal register location, and that it is ready
for the next command.
WE input pin "High".
Motorola Mode Programmed I/O Access (Synchronous)
14-CHANNEL T1/E1/J1 SHORT-HAUL LINE INTERFACE UNIT
47
xr