The VOUT_MARGIN_LOW command loads the device with the voltage to which the power-supply output is to be
changed when the OPERATION command is set to margin low. If the power supply is already operating at margin low,
changing VOUT_MARGIN_LOW has no effect on the output voltage. The device only adjusts the power supply to the
new VOUT_MARGIN_LOW voltage after receiving a new margin low OPERATION command. The 2 data bytes are in
DIRECT format. If the device cannot successfully close-loop margin the power supply, the device keeps attempting to
margin the supply and does the following:
1) Sets the NONE OF THE ABOVE bit in STATUS_BYTE.
2) Sets the NONE OF THE ABOVE and MFR bits in STATUS_WORD.
3) Sets the MARGIN_FAULT bit in STATUS_MFR_SPECIFIC.
4) Notifies the host through ALERT assertion (if enabled in MFR_MODE).
VOUT_SCALE_MONITOR is used in applications where the measured power-supply voltage is not equal to the voltage
at the ADC input. For example, if the ADC input expects a 1.0V input for a 12V output, VOUT_SCALE_MONITOR =
1.0V/12V = 0.0833. In applications where the power-supply output voltage is greater than the device input range, the
output voltage of the power supply is sensed through a resistive voltage-divider. The resistive voltage-divider reduces
or scales the output voltage. The PMBus commands specify the actual power-supply output voltages and not the input
voltage to the ADC. To allow the device to map between the power-supply voltage (such as 12V) and the voltage at
the ADC input, the VOUT_SCALE_MONITOR command is used. The 2 data bytes are in DIRECT format. This value is
dimensionless. For example, if the required scaling factor is 0.0833, then VOUT_SCALE_MONITOR should be set to
0AABh (2731/32,767 = 0.0833).
Table_14._VOUT_SCALE_MONITOR
Note: On the device, the full-scale ADC voltage is 1.225V. A scaling factor where a 1.0V ADC input represents a nominal 100%
voltage level is recommended.
The IOUT_CAL_GAIN command is used to set the ratio of the voltage at the ADC input to the sensed current. The units
of the IOUT_CAL_GAIN factor are 0.1mI. The 2 data bytes are in DIRECT format. For example, if a 10mI sense resis-
tor is used with a 50V/V current-sense amplifier, the IOUT_CAL_GAIN should be set to 500mI or 1388h.
USER_NOTE:_On_the_device,_the_full-scale_ADC_voltage_is_1.225V._The_value_of_the_sense_resistor_and_current-
sense_amplifier_gain_must_be_scaled_appropriately.
30
NOMINAL_VOLTAGE_LEVEL_
MONITORED_(V)
1.2
1.5
1.8
2.5
3.3
12
5
NOMINAL_ADC_INPUT_VOLTAGE_
LEVEL_(V)_(SEE_NOTE)
1.0
1.0
1.0
1.0
1.0
1.0
1.0
RESISTIVE_VOLTAGE-
DIVIDER_RATIO
0.0833
0.833
0.667
0.555
0.303
0.4
0.2
VOUT_SCALE_MONITOR (2Ah)
VOUT_MARGIN_LOW (26h)
IOUT_CAL_GAIN (38h)
VOUT_SCALE_MONITOR_
VALUE_(HEX)
6AAAh
0AABh
470Ah
26C8h
5555h
3333h
1999h