MAX34441EVKIT# Maxim Integrated, MAX34441EVKIT# Datasheet - Page 33

no-image

MAX34441EVKIT#

Manufacturer Part Number
MAX34441EVKIT#
Description
Power Management IC Development Tools MAX34441 Eval Kit
Manufacturer
Maxim Integrated
Type
PWM Controllersr
Series
MAX34441r
Datasheet

Specifications of MAX34441EVKIT#

Rohs
yes
Product
Power Management Development Tools
Tool Is For Evaluation Of
MAX34441
Interface Type
I2C
Maximum Operating Temperature
+ 85 C
Part # Aliases
90-34441#K00
The IOUT_OC_WARN_LIMIT command sets the value of the current that causes an overcurrent warning. This value is
typically less than the overcurrent fault threshold in IOUT_OC_FAULT_LIMIT. The 2 data bytes are in DIRECT format.
In response to violation of the IOUT_OC_WARN_LIMIT, the device does the following:
1) Sets the NONE OF THE ABOVE bit in STATUS_BYTE.
2) Sets the NONE OF THE ABOVE, IOUT, and MFR bits in STATUS_WORD.
3) Sets the OC_WARN bit in STATUS_MFR_SPECIFIC.
4) Notifies the host using ALERT assertion (if enabled in MFR_MODE).
The IOUT_OC_FAULT_LIMIT command sets the value of the current that causes an overcurrent fault. The factory
default value for IOUT_OC_FAULT_LIMIT is 0000h. This value disables the device from measuring current. Any nonzero
positive value written to IOUT_OC_FAULT_LIMIT causes the device to enable current measurement. The 2 data bytes
are in DIRECT format. In response to violation of the IOUT_OC_FAULT_LIMIT, the device does the following:
1) Sets the IOUT_OC bit in STATUS_BYTE.
2) Sets the IOUT, IOUT_OC, and MFR bits in STATUS_WORD.
3) Sets the OC_FAULT bit in STATUS_MFR_SPECIFIC.
4) Responds as specified in the MFR_FAULT_RESPONSE.
5) Notifies the host using ALERT assertion (if enabled in MFR_MODE).
The OT_FAULT_LIMIT command sets the temperature, in degrees Celsius, of the selected temperature sensor at which
an overtemperature fault is detected. The 2 data bytes are in DIRECT format. In response to the OT_FAULT_LIMIT being
exceeded, the device does the following:
1) Sets the TEMPERATURE bit in STATUS_BYTE.
2) Sets the TEMPERATURE and MFR bits in STATUS_WORD.
3) Sets the OT_FAULT bit in STATUS_MFR_SPECIFIC.
4) Responds as specified in MFR_FAULT_RESPONSE.
5) Notifies the host using ALERT assertion (if enabled in MFR_MODE).
Table_18._IOUT_OC_FAULT_LIMIT
IOUT_OC_FAULT_LIMIT_VALUE
PMBus 5-Channel Power-Supply Manager
8000h to FFFFh
0001h to 7FFFh
0000h
and Intelligent Fan Controller
Negative values are invalid.
Current measurement disabled.
Current measurement enabled.
DEVICE_RESPONSE_(ON_THE_ASSOCIATED_PAGE)
IOUT_OC_FAULT_LIMIT (4Ah)
IOUT_OC_WARN_LIMIT (46h)
OT_FAULT_LIMIT (4Fh)
33