MAX34441EVKIT# Maxim Integrated, MAX34441EVKIT# Datasheet - Page 39

no-image

MAX34441EVKIT#

Manufacturer Part Number
MAX34441EVKIT#
Description
Power Management IC Development Tools MAX34441 Eval Kit
Manufacturer
Maxim Integrated
Type
PWM Controllersr
Series
MAX34441r
Datasheet

Specifications of MAX34441EVKIT#

Rohs
yes
Product
Power Management Development Tools
Tool Is For Evaluation Of
MAX34441
Interface Type
I2C
Maximum Operating Temperature
+ 85 C
Part # Aliases
90-34441#K00
The MFR_MODE command is used to configure the device to support manufacturer specific commands. The MFR_
MODE command is described in Table 26.
Table_26._MFR_MODE
Note: If a dual tachometer fan is used, it is recommended that the slower tachometer signal be presented to the TACH pin when
TACHSEL = 0.
10:9
BIT_
5:0
15
14
13
12
11
8
7
6
FORCE_NV_FAULT_LOG
CLEAR_NV_FAULT_LOG
PSEN_PP_OD
SOFT_RESET
PSEN_HI_LO
PGTIME[1:0]
PG_SELECT
BIT_NAME
PMBus 5-Channel Power-Supply Manager
ALERT
0
0
Setting this bit to 1 forces the device to log data into the nonvolatile fault log. Once set, the
device clears this bit when the action is completed. The host must set again for subsequent
action. If an error occurs during this action, the device sets the CML bit in STATUS_BYTE
and STATUS_WORD; no bits are set in STATUS_CML.
Setting this bit to 1 forces the device to clear the nonvolatile fault log by writing FFh to all
byte locations. Once set, the device clears this bit when the action is completed. The host
must set again for subsequent action. If an error occurs during this action, the device sets
the CML bit in STATUS_BYTE and STATUS_WORD; no bits are set in STATUS_CML.
0 = ALERT disabled (device does not respond to ARA).
1 = ALERT enabled (device responds to ARA and ARA must be used).
This bit always returns a 0.
This bit must be set, then cleared and set again within 8ms for a soft reset to occur.
0 = PG/TACHSEL output is power-good indication.
1 = PG/TACHSEL output is TACHSEL (for dual tachometer fans). For dual tachometer fans,
this output is toggled every 500ms.
Applies to all PSEN outputs.
0 = PSEN push-pull output.
1 = PSEN open-drain output.
Applies to all PSEN outputs.
0 = PSEN active low.
1 = PSEN active high.
These bits always return a 0.
PGTIME1
0
0
1
1
and Intelligent Fan Controller
PGTIME0
0
1
0
1
MEANING
TIME_FROM_POWER_GOOD_DETERMINED_
UNTIL_PG_OUTPUT_IS_ASSERTED_(ms)
Immediately
1000
100
500
MFR_MODE (D1h)
39