MAX34441EVKIT# Maxim Integrated, MAX34441EVKIT# Datasheet - Page 36

no-image

MAX34441EVKIT#

Manufacturer Part Number
MAX34441EVKIT#
Description
Power Management IC Development Tools MAX34441 Eval Kit
Manufacturer
Maxim Integrated
Type
PWM Controllersr
Series
MAX34441r
Datasheet

Specifications of MAX34441EVKIT#

Rohs
yes
Product
Power Management Development Tools
Tool Is For Evaluation Of
MAX34441
Interface Type
I2C
Maximum Operating Temperature
+ 85 C
Part # Aliases
90-34441#K00
PMBus 5-Channel Power-Supply Manager
and Intelligent Fan Controller
The STATUS_WORD command returns 2 bytes of information with a summary of the reason for a fault. The low byte of
the STATUS_WORD is the same data as the STATUS_BYTE. Table 21 describes the STATUS_WORD message content.
The STATUS_VOUT command returns 1 byte of information with contents as described in Table 22.
Table_22._STATUS_VOUT
The STATUS_CML command returns 1 byte of information with contents as described in Table 23.
Table_23._STATUS_CML
36
Table_21._STATUS_WORD
BIT_
BIT_
BIT_
1:0
5:1
9:6
15
14
13
12
11
10
7
6
5
4
3
2
7
6
0
5
4
3
2
1
0
NONE OF THE ABOVE A fault or warning not listed in bits [7:1] has occurred.
FAULT_LOG_FULL
TON_MAX_FAULT
VOUT_OV_FAULT
VOUT_OV_WARN
VOUT_UV_FAULT
VOUT_UV_WARN
POWER_GOOD#
TEMPERATURE
COMM_FAULT
DATA_FAULT
BIT_NAME
BIT_NAME
BIT_NAME
VOUT_OV
IOUT_OC
VOUT
FANS
IOUT
CML
MFR
0
0
0
0
0
0
An invalid or unsupported command has been received.
An invalid or unsupported data has been received.
These bits always return a 0.
MFR_NV_FAULT_LOG is full and needs to be cleared.
An output voltage fault or warning or TON_MAX_FAULT has occurred.
An overcurrent fault or warning has occurred.
This bit always returns a 0.
A bit in STATUS_MFR_SPECIFIC has been set.
A power-supply voltage has fallen from POWER_GOOD_ON to less than POWER_GOOD_OFF.
A fan fault has occurred.
These bits always return a 0.
An overvoltage fault has occurred.
An overcurrent fault has occurred.
This bit always returns a 0.
A temperature fault or warning has occurred.
A communication, memory, or logic fault has occurred.
VOUT overvoltage fault.
VOUT overvoltage warning.
VOUT undervoltage warning.
VOUT undervoltage fault.
This bit always returns a 0.
TON maximum fault.
These bits always return a 0.
MEANING
MEANING
MEANING
STATUS_WORD (79h)
STATUS_VOUT (7Ah)
STATUS_CML (7Eh)

Related parts for MAX34441EVKIT#