EVAL6472PD STMicroelectronics, EVAL6472PD Datasheet - Page 56

no-image

EVAL6472PD

Manufacturer Part Number
EVAL6472PD
Description
Power Management IC Development Tools L6472PD 7.0A w/SPI dSPIN 8 to 45V EVAL
Manufacturer
STMicroelectronics
Type
Motor / Motion Controllers & Driversr
Datasheet

Specifications of EVAL6472PD

Product Category
Power Management IC Development Tools
Rohs
yes
Product
Evaluation Boards
Tool Is For Evaluation Of
L6472PD
Input Voltage
8 V to 45 V
Output Voltage
8 V to 45 V
Interface Type
SPI
Output Current
7 A
For Use With
L6472

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EVAL6472PD
Manufacturer:
ST
0
Programming manual
9.2.5
Note:
9.2.6
56/68
Any attempt to read an inexistent register (wrong address value) causes the command to be
ignored and WRONG_CMD flag to rise at the end of command byte as if an unknown
command code is sent.
Run (DIR, SPD)
Table 38.
The Run command produces a motion at SPD speed; the direction is selected by the DIR
bit: '1' forward or '0' reverse. The SPD value is expressed in step/tick (format unsigned fixed
point 0.28) which is the same format as the SPEED register (see
The SPD value should be lower than MAX_SPEED and greater than MIN_SPEED
otherwise the Run command is executed at MAX_SPEED or MIN_SPEED respectively.
This command keeps the BUSY flag low until the target speed is reached.
This command can be given anytime and is immediately executed.
StepClock (DIR)
Table 39.
The StepClock command switches the device in step-clock mode (see
imposes the forward (DIR = '1') or reverse (DIR = '0') direction.
When the device is in step-clock mode the SCK_MOD flag in the STATUS register is raised
and the motor is always considered stopped (see
The device exits from step-clock mode when a constant speed, absolute positioning or
motion command is sent through SPI. Motion direction is imposed by the respective
StepClock command argument and can by changed by a new StepClock command without
exiting step-clock mode.
Events that cause bridges to be forced into high-impedance state (overtemperature,
overcurrent, etc.) do not cause the device to leave step-clock mode. StepClock command
does not force the BUSY flag low. This command can only be given when the motor is
stopped. If a motion is in progress the motor should be stopped and it is then possible to
send a StepClock command.
Any attempt to perform a StepClock command when the motor is running causes the
command to be ignored and the NOTPERF_CMD flag to rise (see
Bit 7
Bit 7
X
0
0
Bit 6
X
1
Bit 6
Run command structure
StepClock command structure
1
Bit 5
X
0
Bit 5
0
Bit 4
X
1
Doc ID 022729 Rev 2
Bit 4
1
SPD (Byte 1)
SPD (Byte 0)
SPD (Byte 2)
Bit 3
Bit 3
1
0
Section 6.7.5
Bit 2
0
Bit 2
0
Bit 1
0
Bit 1
and
0
Section
Section
Section
Bit 0
DIR
Section
Bit 0
DIR
9.1.4).
9.1.19).
9.1.18).
6.7.5) and
From host
From host
From host
From host
From host
L6472

Related parts for EVAL6472PD