2ED100E12-F_EVAL Infineon Technologies, 2ED100E12-F_EVAL Datasheet - Page 12

no-image

2ED100E12-F_EVAL

Manufacturer Part Number
2ED100E12-F_EVAL
Description
Power Management IC Development Tools Eval Board EconoDual
Manufacturer
Infineon Technologies
Datasheet
Module
FF450R06ME3
FF600R06ME3
FF150R12ME3
FF225R12ME3
FF300R12ME3
FF450R12ME3
FF150R12MS4
FF225R12MS4
The curve from Figure 5 can be used for max. switching frequency estimation of EconoDUAL
is listed bellow:
Table 3
FF300R12MS4
3.4
The short circuit protection of the Evaluation Driver Board basically relies on 2-level Turn-off function already
implemented in the TD350. Thanks to this operation mode, the collector-emitter overvoltage, which is a result
of the stray inductance and the collector current slope, is limited
the second level of the turn-off voltage. If the stray inductance is not higher than 30µH the 2ED100E12-F can
switch-off the IGBT safely. If L
6a, 6b) must be performed. The typical waveforms of a FF225R12ME3 module with optimized 2-level Turn-
off circuit, during switching-off under short circuit condition are shown on Figure 6c.
Figure 6
Note that the 2-level Turn-off on the Evaluation Driver Board is always enabled, therefore the propagation
delay time t
calculated as t
6)
Application Note
Detailed information about this function available in: TD350 datasheet and AN1944
pd(on)
Estimated max. IGBT switching frequency and PWM minimum dead times
for 2ED100E12-F and EconoDUAL
Short circuit protection
a, b) 2-level Turn-off circuit with values to be adjusted if L
short circuit conditions
pd
+T
R
1,5 /
3,0 / 0,7
8,2 / 1,3
3,3 / 3,3
2,4 / 2,5
1,6 / 1,7
7,5 / 1,7
4,7 / 1,7
2,7 / 1,7
and t
EXT
a
and equals approximately 1,5µs.
[Ω]/R
pd(off)
INT
[Ω] f
are extended by the time T
σ
is bigger, an additional adjustment of R
no Q
15 kHz – limited by DC/DC power 7 kHz
70 kHz – limited by DC/DC power 31 kHz
45 kHz – limited by DC/DC power 35 kHz
35 kHz – limited by DC/DC power 28 kHz
22 kHz – limited by DC/DC power 17 kHz
60 kHz – limited by DC/DC power 28 kHz
40 kHz – limited by DC/DC power 20 kHz
30 kHz – limited by DC/DC power 18kHz
S
@Ta=25°C
G
data
TM
modules
12
a
. During normal operation the delay time can be
6)
f
. This requires appropriate setting of T
S
@Ta=70°C
5T
, R
Q
>30nH, c) switching-off under
5B
Driver for EconoDUAL
, C
f
3,3 kHz
14 kHz
15 kHz
13 kHz
8 kHz
13 kHz
9 kHz
8 kHz
S
@Ta=85°C
5T
, C
5B
, D
6T
Application Note
and D
t
1µs
1µs
1µs
1µs
1µs
1µs
1µs
1µs
TM
TD
V1.0, 2006-05
AN2006-04
(dead time)
modules as
6B
(Figure
a
and
TM

Related parts for 2ED100E12-F_EVAL