M27C512-90F6 STMicroelectronics, M27C512-90F6 Datasheet - Page 8

IC EPROM 512KBIT 90NS 28CDIP

M27C512-90F6

Manufacturer Part Number
M27C512-90F6
Description
IC EPROM 512KBIT 90NS 28CDIP
Manufacturer
STMicroelectronics
Datasheets

Specifications of M27C512-90F6

Format - Memory
EPROMs
Memory Type
UV EPROM
Memory Size
512K (64K x 8)
Speed
90ns
Interface
Parallel
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Package / Case
28-CDIP (0.600", 15.24mm) Window
Memory Configuration
64K X 8
Access Time
90ns
Supply Voltage Range
4.5V To 5V
Memory Case Style
DIP
No. Of Pins
28
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M27C512-90F6
Manufacturer:
ST
Quantity:
1 450
Part Number:
M27C512-90F6
Manufacturer:
ST
Quantity:
5 704
Part Number:
M27C512-90F6
Manufacturer:
ST
Quantity:
5 704
Part Number:
M27C512-90F6
Manufacturer:
ST
Quantity:
2 124
Part Number:
M27C512-90F6
Manufacturer:
ST
0
Part Number:
M27C512-90F6
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
M27C512-90F6
Quantity:
1 000
Part Number:
M27C512-90F6L
Manufacturer:
AD
Quantity:
196
Part Number:
M27C512-90F6L
Manufacturer:
ST
0
Part Number:
M27C512-90F6L
Manufacturer:
ST
Quantity:
20 000
Part Number:
M27C512-90F6LGN (PB)
Manufacturer:
ST
0
M27C512
ERASURE OPERATION (APPLIES FOR UV EPROM)
The erasure characteristics of the M27C512 is
such that erasure begins when the cells are ex-
posed to light with wavelengths shorter than ap-
proximately 4000 Å. It should be noted that
sunlight and some type of fluorescent lamps have
wavelengths in the 3000-4000 Å range.
Research shows that constant exposure to room
level fluorescent lighting could erase a typical
M27C512 in about 3 years, while it would take ap-
proximately 1 week to cause erasure when ex-
posed to direct sunlight. If the M27C512 is to be
exposed to these types of lighting conditions for
extended periods of time, it is suggested that
8/22
opaque labels be put over the M27C512 window to
prevent unintentional erasure. The recommended
erasure procedure for the M27C512 is exposure to
short wave ultraviolet light which has wavelength
2537 Å. The integrated dose (i.e. UV intensity x
exposure time) for erasure should be a minimum
of 15 W-sec/cm
age is approximately 15 to 20 minutes using an ul-
traviolet lamp with 12000 µW/cm
The M27C512 should be placed within 2.5 cm (1
inch) of the lamp tubes during the erasure. Some
lamps have a filter on their tubes which should be
removed before erasure.
2
. The erasure time with this dos-
2
power rating.

Related parts for M27C512-90F6